GlobeCore / Configurator CMM-10A

Configurator CMM-10A

CMM-10A

Equipment configurations that are not included in this configurator can be implemented via a separate request to [email protected].

*Product and option prices are approximate estimations.
You can request specific prices through the contact form.
Loading...

Components type is basic

Components type is premium

Manual performance adjustment by valves (or smooth performance adjustment, see option). Functioning in semi-automatic modes. Stepped or smooth (see option) oil heating. PLC control

Automatic performance adjustment. Functioning in automatic modes. Smooth oil heating. Control from PLC + HMI

Performance adjustment with manual valves

Performance adjustment of the vacuum pump is executed with a regulator on the control panel by means of a valve with an electric drive. Visual monitoring of the flow rate is by the flow meter indicator

Performance adjustment of the vacuum pump is executed by setpoint selecting at the control panel screen for maintaining the level in the vacuum column. Pump operation is smooth throughout the entire control range. There is a digital meter to control oil flow

The controller program switches the heater stages by contactors according to the algorithm. Operator sets the temperature and it is kept constant automatically

Solid state relay (SSR) adjusts the heater stages' current smoothly and non-contactly. The P-Int-Derivative Controller

The language of text at the controller screen, devices, controls and the language of the technical documentation is English

The language of text at the controller screen, devices, controls and the language of the technical documentation is Spanish

Mechanical flow meter with total flow display

Digital flow meter with current and total flow display

Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit

Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which was processed by the unit

Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit and which was processed by the unit

The cable is fitted with an industrial sealed connector, consisting of an internal plug and a cable socket

The cable wires' ends are fitted with a crimp terminals

The cable is fitted with an industrial sealed connector, consisting of an internal socket and a cable plug