{"id":352472,"date":"2021-05-12T12:18:18","date_gmt":"2021-05-12T12:18:18","guid":{"rendered":"https:\/\/globecore.com\/products\/cable-oil-processing\/cmm-1co-cable-oil-degassing-unit\/"},"modified":"2026-11-26T10:02:30","modified_gmt":"2026-11-26T10:02:30","slug":"cmm-1co-cable-oil-degassing-unit","status":"publish","type":"page","link":"https:\/\/globecore.com\/de\/products\/cable-oil-processing\/cmm-1co-cable-oil-degassing-unit\/","title":{"rendered":"Kabel\u00f6lentgasungsanlage CMM-1CO"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>The CMM-1CO unit is designed to remove solid particles, gas, and moisture from cable oil, store portions of prepared oil, and supply it to oil-filled cable lines with voltages up to 500\u202fkV. The unit can also be used for evacuation of transformers and other oil-filled equipment, with a processing capacity of at least 1\u202fm\u00b3\/hour.<\/p>\n","protected":false},"author":59,"featured_media":145733,"parent":352454,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"templates\/single-product.php","meta":{"_acf_changed":false,"_themeisle_gutenberg_block_has_review":false,"_wpml_language_code":"","footnotes":""},"categories":[1892],"class_list":["post-352472","page","type-page","status-publish","has-post-thumbnail","hentry","category-oil-maintenance-de","oil_type-kabelol","process_type-dehydrierung","process_type-entgasung","process_type-filtration-de"],"acf":{"add_tab":[{"tab_title":"Beschreibung","tab_content":"Die Anlage CMM-1CO dient zur Entfernung von Feststoffpartikeln, Gasen und Feuchtigkeit aus <strong>Kabel\u00f6l<b><\/b><\/strong>, zur Lagerung von aufbereitetem Kabel\u00f6l sowie zum Nachf\u00fcllen von \u00d6l in \u00d6lkabelleitungen (OF)<b> <\/b> mit einer Spannung von bis zu 500 kV. Die Anlage kann auch zur Evakuierung von <strong>Transformatoren<b><\/b><\/strong> und anderen Betriebsmitteln eingesetzt werden.\r\n\r\nDie Anlage kann Kabel\u00f6l mit folgenden Ausgangsparametern aufbereiten:\r\n<ul>\r\n \t<li>Feuchtigkeitsgehalt unter 100 ppm;<\/li>\r\n \t<li>Reinheitsklasse gem\u00e4\u00df <strong>ISO<b><\/b><\/strong> <strong>4406<\/strong> -\/19\/16 oder besser.<\/li>\r\n<\/ul>\r\nAlle Komponenten der Anlage, mit Ausnahme der Lagertanks f\u00fcr aufbereitetes \u00d6l, sind in einem Container untergebracht. Die Vorderseite und die Seiten des Containers sind mit Zugangst\u00fcren f\u00fcr die Wartung der Anlage ausgestattet.\r\n\r\nDie Anlage CMM-1CO besteht aus einer <strong>Vakuumkammer<b><\/b><\/strong>, einer Einlasspumpe, einem \u00d6lerhitzer, einer Auslasspumpe, Grob- und Fein<strong>filtern<b><\/b><\/strong>, einem Schaltschrank, <strong>einer Vakuumpumpe<b><\/b><\/strong> und einer Vorvakuumpumpe sowie \u00d6llagertanks."}],"add_def_tab":[{"tab_title":"Technische","tab_content":"<table>\r\n<tbody>\r\n<tr>\r\n<td><b>Nr.<\/b><\/td>\r\n<td style=\"text-align: center;\"><b>Parameter<\/b><\/td>\r\n<td style=\"text-align: center;\"><b>Wert<\/b><\/td>\r\n<\/tr>\r\n<tr>\r\n<td>1<\/td>\r\n<td>Minimaler Durchsatz, m<sup>3<\/sup>\/h<\/td>\r\n<td style=\"text-align: center;\">1<\/td>\r\n<\/tr>\r\n<tr>\r\n<td rowspan=\"7\">2*<\/td>\r\n<td style=\"text-align: left;\" colspan=\"2\">Parameter des aufbereiteten \u00d6ls:<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u2013 maximaler Gasgehalt, Vol.-%<\/td>\r\n<td style=\"text-align: center;\">0,05<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u2013 maximaler Feuchtigkeitsgehalt, ppm<\/td>\r\n<td style=\"text-align: center;\">5<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u2013 Reinheitsklasse gem\u00e4\u00df ISO 4406<\/td>\r\n<td style=\"text-align: center;\">-\/14\/12<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u2013 maximaler Feststoffpartikelgehalt, g\/t<\/td>\r\n<td style=\"text-align: center;\">8<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u2013 Filterfeinheit, \u03bcm<\/td>\r\n<td style=\"text-align: center;\">2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u2013 minimale Durchschlagspannung, kV<\/td>\r\n<td style=\"text-align: center;\">70<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>3<\/td>\r\n<td>Maximale \u00d6ltemperatur im Heizbetrieb, \u00b0C<\/td>\r\n<td style=\"text-align: center;\">70<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>4<\/td>\r\n<td>Filtrationskoeffizient<\/td>\r\n<td style=\"text-align: center;\">\u226550<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>5<\/td>\r\n<td>Auslassdruck (Nennwert\/Maximalwert), bar<\/td>\r\n<td style=\"text-align: center;\">2\/12<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>6<\/td>\r\n<td>Leistung des \u00d6lerhitzers, kW<\/td>\r\n<td style=\"text-align: center;\">18<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>7<\/td>\r\n<td>Maximale Oberfl\u00e4chenleistungsdichte des \u00d6lerhitzers, W\/cm<sup>2<\/sup><\/td>\r\n<td style=\"text-align: center;\">1,15<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>8<\/td>\r\n<td>Maximaler Leistungsbedarf, kW<\/td>\r\n<td style=\"text-align: center;\">27<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>10<\/td>\r\n<td>Fassungsverm\u00f6gen des \u00d6llagertanks, m<sup>3<\/sup><\/td>\r\n<td style=\"text-align: center;\">0,7<\/td>\r\n<\/tr>\r\n<tr>\r\n<td rowspan=\"3\">11<\/td>\r\n<td colspan=\"2\">Stromversorgung<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u2013 Spannung, V<\/td>\r\n<td style=\"text-align: center;\" rowspan=\"2\">nach Kundenanforderung<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u2013 Wechselstromfrequenz, Hz<\/td>\r\n<\/tr>\r\n<tr>\r\n<td rowspan=\"4\">12<\/td>\r\n<td colspan=\"2\">Abmessungen, mm<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u2013 L\u00e4nge<\/td>\r\n<td style=\"text-align: center;\">2.450<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u2013 H\u00f6he<\/td>\r\n<td style=\"text-align: center;\">1.700<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u2013 Breite<\/td>\r\n<td style=\"text-align: center;\">1.550<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>13<\/td>\r\n<td>Gewicht, kg<\/td>\r\n<td style=\"text-align: center;\">1.800<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<i>Hinweis \u2013 *<\/i> Ausgangsqualit\u00e4t des \u00d6ls:\r\n<ul>\r\n \t<li>Gasgehalt unter 10,5 Vol.-%;<\/li>\r\n \t<li>Feuchtigkeitsgehalt unter 0,01 % (100 ppm);<\/li>\r\n \t<li>Temperatur \u00fcber 0 \u00b0C.<\/li>\r\n<\/ul>"},{"tab_title":"Vorteile","tab_content":"<ul>\r\n \t<li>Eine einzige Anlage f\u00fcr alle Aufgaben der Kabel\u00f6laufbereitung: Entw\u00e4sserung und Entgasung des \u00d6ls, Evakuierung von Kabelleitungen und Bef\u00fcllung von Nachf\u00fcllbeh\u00e4ltern.<\/li>\r\n \t<li>Erh\u00f6hte Betriebssicherheit von \u00d6lkabelleitungen.<\/li>\r\n \t<li>Einfache Bedienung und Wartung;<\/li>\r\n \t<li>Die Anlage kann in station\u00e4rer Ausf\u00fchrung (im Container, auf Grundrahmen oder mit Schutzplane) oder in mobiler Ausf\u00fchrung (auf Lenkrollen oder Anh\u00e4nger) hergestellt werden.<\/li>\r\n<\/ul>"},{"tab_title":"Configurator","tab_content":"[ezfc id='119' \/]"}],"add_video_tab":[{"video_tab_title":"Video","add_video_id":[{"video_id":"YifsNCdv6DQ"},{"video_id":"Z2V118mGCtI"},{"video_id":"ACM7txy9w6w"}]}],"add_gallery_tab":[{"gallery_tab_title":"Gallery","add_img":[352467,352466,352465]}],"add_price_tab":[{"price_tab_title":"Get a Quote"}],"product_faq_title":"FAQ","product_faq_items":null},"language":"de","_links":{"self":[{"href":"https:\/\/globecore.com\/de\/wp-json\/wp\/v2\/pages\/352472","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/globecore.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/globecore.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/globecore.com\/de\/wp-json\/wp\/v2\/users\/59"}],"replies":[{"embeddable":true,"href":"https:\/\/globecore.com\/de\/wp-json\/wp\/v2\/comments?post=352472"}],"version-history":[{"count":2,"href":"https:\/\/globecore.com\/de\/wp-json\/wp\/v2\/pages\/352472\/revisions"}],"predecessor-version":[{"id":352486,"href":"https:\/\/globecore.com\/de\/wp-json\/wp\/v2\/pages\/352472\/revisions\/352486"}],"up":[{"embeddable":true,"href":"https:\/\/globecore.com\/de\/wp-json\/wp\/v2\/pages\/352454"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/globecore.com\/de\/wp-json\/wp\/v2\/media\/145733"}],"wp:attachment":[{"href":"https:\/\/globecore.com\/de\/wp-json\/wp\/v2\/media?parent=352472"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/globecore.com\/de\/wp-json\/wp\/v2\/categories?post=352472"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}