{"id":352728,"date":"2025-09-04T11:05:20","date_gmt":"2025-09-04T11:05:20","guid":{"rendered":"https:\/\/globecore.com\/news\/oil-dewatering-in-power-transformers\/"},"modified":"2026-11-27T10:16:58","modified_gmt":"2026-11-27T10:16:58","slug":"oil-dewatering-in-power-transformers","status":"publish","type":"post","link":"https:\/\/globecore.com\/fr\/oil-maintenance-fr\/oil-dewatering-in-power-transformers\/","title":{"rendered":"D\u00e9shydratation de l\u2019huile dans les transformateurs de puissance"},"content":{"rendered":"<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">La d\u00e9shydratation de l\u2019huile est l\u2019un des processus les plus importants pour garantir le fonctionnement fiable des transformateurs de puissance, qui comptent parmi les composants les plus co\u00fbteux de l\u2019ensemble du syst\u00e8me d\u2019alimentation \u00e9lectrique. Toute d\u00e9faillance de ces \u00e9quipements peut entra\u00eener de graves perturbations de l\u2019approvisionnement en \u00e9nergie et des pertes financi\u00e8res importantes pour les entreprises et les fournisseurs d\u2019\u00e9lectricit\u00e9. \u00c9tant donn\u00e9 que la plupart des d\u00e9faillances des transformateurs sont li\u00e9es \u00e0 la d\u00e9gradation du syst\u00e8me d\u2019isolation, le maintien de la qualit\u00e9 de l\u2019huile isolante rev\u00eat une importance primordiale. L\u2019huile de transformateur assure non seulement une rigidit\u00e9 di\u00e9lectrique \u00e9lev\u00e9e, mais p\u00e9n\u00e8tre \u00e9galement dans l\u2019isolation solide afin d\u2019\u00e9vacuer la chaleur et de la transf\u00e9rer vers le syst\u00e8me de refroidissement. Lorsque de l\u2019oxyg\u00e8ne, des contaminants et, surtout, de l\u2019humidit\u00e9 p\u00e9n\u00e8trent dans l\u2019huile, l\u2019oxydation s\u2019acc\u00e9l\u00e8re, le vieillissement s\u2019intensifie et le risque de claquage de l\u2019isolation augmente consid\u00e9rablement.<\/span><\/p>\n<h2 style=\"text-align: center;\"><span style=\"font-weight: 400;\">Impact de l\u2019eau sur l\u2019huile de transformateur et l\u2019isolation<\/span><\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">La contamination par l\u2019eau est l\u2019une des formes les plus dangereuses de d\u00e9gradation de l\u2019huile. M\u00eame une faible quantit\u00e9 d\u2019humidit\u00e9 acc\u00e9l\u00e8re consid\u00e9rablement le vieillissement de l\u2019isolation. Par exemple, l\u2019isolation des enroulements pr\u00e9sentant une teneur en humidit\u00e9 de 1 % vieillit jusqu\u2019\u00e0 dix fois plus rapidement que celle dont la teneur en humidit\u00e9 n\u2019est que de 0,1 %. L\u2019eau affecte l\u2019huile de transformateur de plusieurs mani\u00e8res :<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">L\u2019eau d\u00e9cant\u00e9e s\u2019accumule au fond de la cuve du transformateur. Bien qu\u2019elle ne r\u00e9duise pas directement la rigidit\u00e9 di\u00e9lectrique, sa pr\u00e9sence indique que l\u2019huile contient \u00e9galement de l\u2019eau dissoute.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">L\u2019eau dissoute r\u00e9duit la tension de claquage et p\u00e9n\u00e8tre g\u00e9n\u00e9ralement dans l\u2019huile depuis l\u2019atmosph\u00e8re. Bien qu\u2019une \u00e9limination partielle puisse \u00eatre r\u00e9alis\u00e9e par centrifugation, son \u00e9limination compl\u00e8te n\u00e9cessite un traitement sous vide.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">L\u2019eau li\u00e9e se forme comme sous-produit de l\u2019oxydation de l\u2019huile et constitue l\u2019un des premiers signes de vieillissement. Aux temp\u00e9ratures \u00e9lev\u00e9es r\u00e9gnant entre les enroulements et le noyau magn\u00e9tique en acier, l\u2019eau dissoute se transforme en vapeur, puis se condense et se dissout \u00e0 nouveau dans les couches d\u2019huile plus froides.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">L\u2019eau \u00e9mulsionn\u00e9e se pr\u00e9sente sous la forme de gouttelettes microscopiques dispers\u00e9es dans l\u2019huile. Cette forme d\u2019humidit\u00e9 est particuli\u00e8rement probl\u00e9matique, car elle ne peut pas \u00eatre \u00e9limin\u00e9e par chauffage, d\u00e9cantation ou simple filtration.<\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">La migration de l\u2019eau entre l\u2019huile et l\u2019isolation solide d\u00e9pend fortement de la temp\u00e9rature. Lorsque la temp\u00e9rature du transformateur augmente, l\u2019eau migre de l\u2019isolation papier vers l\u2019huile ; lorsque la temp\u00e9rature diminue, le ph\u00e9nom\u00e8ne inverse se produit. Les profils thermiques non uniformes \u00e0 l\u2019int\u00e9rieur du transformateur, dus \u00e0 la g\u00e9om\u00e9trie des enroulements, aux d\u00e9p\u00f4ts de boues ou \u00e0 la conception des canaux de refroidissement, rendent la gestion de l\u2019humidit\u00e9 encore plus complexe. Au fil du temps, la pr\u00e9sence d\u2019eau r\u00e9duit la rigidit\u00e9 di\u00e9lectrique, augmente le facteur de dissipation di\u00e9lectrique et entra\u00eene des d\u00e9fauts \u00e9lectriques tels que les d\u00e9charges partielles, susceptibles d\u2019\u00e9voluer en arcs \u00e9lectriques et de provoquer de graves d\u00e9faillances du transformateur.<\/span><\/p>\n<h2 style=\"text-align: center;\"><span style=\"font-weight: 400;\">D\u00e9shydratation de l\u2019huile : principes et m\u00e9thodes<\/span><\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">L\u2019\u00e9limination de l\u2019eau contenue dans l\u2019huile de transformateur peut \u00eatre r\u00e9alis\u00e9e \u00e0 l\u2019aide de diff\u00e9rentes technologies, mais les plus couramment utilis\u00e9es sont le s\u00e9chage par z\u00e9olithe et le traitement thermique sous vide.<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Le s\u00e9chage par z\u00e9olithe est particuli\u00e8rement efficace pour la d\u00e9shydratation de l\u2019huile et permet d\u2019augmenter la tension de claquage de 10\u201315 kV \u00e0 60\u201370 kV en un seul passage. Toutefois, les cartouches de z\u00e9olithe n\u00e9cessitent une r\u00e9activation p\u00e9riodique apr\u00e8s saturation, ce qui les rend moins pratiques pour les processus continus de longue dur\u00e9e. Elles sont particuli\u00e8rement adapt\u00e9es aux interventions rapides ou \u00e0 une \u00e9tape de pr\u00e9s\u00e9chage avant un traitement sous vide plus pouss\u00e9.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Le s\u00e9chage thermique sous vide est une m\u00e9thode plus polyvalente. Il repose sur le principe selon lequel l\u2019eau bout \u00e0 des temp\u00e9ratures plus basses lorsque la pression diminue. Pendant le traitement, l\u2019huile de transformateur est pr\u00e9chauff\u00e9e \u00e0 environ 50\u201355 \u00b0C, puis introduite dans une colonne sous vide. Sous vide pouss\u00e9, l\u2019huile se r\u00e9partit en une fine pellicule sur les surfaces des filtres-activateurs, lib\u00e9rant rapidement l\u2019eau et les gaz. Ce processus permet de r\u00e9aliser simultan\u00e9ment le s\u00e9chage et le d\u00e9gazage de l\u2019huile sans g\u00e9n\u00e9rer de d\u00e9chets solides n\u00e9cessitant une \u00e9limination. Les unit\u00e9s de traitement thermique sous vide sont donc largement utilis\u00e9es aussi bien pour les op\u00e9rations de maintenance que pour les interventions de grande envergure sur les transformateurs.<br \/>\n<a href=\"https:\/\/globecore.com\/wp-content\/uploads\/2018\/04\/CMM-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-53962 lazyload\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" alt=\"\" width=\"600\" height=\"293\" title=\"\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" data-src=\"https:\/\/globecore.com\/wp-content\/uploads\/2018\/04\/CMM-1-600x293.jpg\" data-srcset=\"https:\/\/globecore.com\/wp-content\/uploads\/2018\/04\/CMM-1-600x293.jpg 600w, https:\/\/globecore.com\/wp-content\/uploads\/2018\/04\/CMM-1.jpg 845w\"><\/a><\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><\/li>\n<\/ul>\n<h2 style=\"text-align: center;\"><span style=\"font-weight: 400;\">Syst\u00e8mes de d\u00e9shydratation et de d\u00e9gazage de l\u2019huile GlobeCore<\/span><\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\"><em><strong>GlobeCore<\/strong><\/em> fabrique une large gamme d\u2019unit\u00e9s de la s\u00e9rie <a href=\"https:\/\/globecore.com\/products\/degassing-thermal-vacuum-drying-oil\/uvm-47-mobile-oil-plant\/\"><strong>CMM<\/strong><\/a> destin\u00e9es au s\u00e9chage thermique sous vide et au d\u00e9gazage des huiles de transformateur. Ces syst\u00e8mes sont \u00e9quip\u00e9s d\u2019une technologie de vide \u00e0 deux \u00e9tages, garantissant un d\u00e9gazage plus pouss\u00e9 et une \u00e9limination plus approfondie de l\u2019humidit\u00e9. Leurs fonctions comprennent :<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">D\u00e9shydratation et s\u00e9chage de l\u2019huile.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">D\u00e9gazage et filtration.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Mise sous vide des transformateurs et remplissage d\u2019huile sous vide.<\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Apr\u00e8s traitement dans les unit\u00e9s GlobeCore, l\u2019huile de transformateur atteint une tension de claquage d\u2019au moins 70 kV, une teneur en gaz inf\u00e9rieure \u00e0 0,1 % et une teneur en eau inf\u00e9rieure \u00e0 10 g\/t. La gamme de produits comprend des mod\u00e8les dont le d\u00e9bit de traitement varie de 1 \u00e0 15 m\u00b3\/h. Pour les interventions sur site, <em><strong>GlobeCore<\/strong><\/em> propose \u00e9galement des versions mont\u00e9es sur remorque, permettant un d\u00e9ploiement rapide sur les sites d\u2019installation des transformateurs.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Lorsque la teneur en humidit\u00e9 d\u00e9passe 100 ppm, des cartouches de z\u00e9olithe (<a href=\"https:\/\/globecore.com\/products\/zeolite-oil-drying-units\/zp-130-sorbent-cartridges\/\"><strong>ZP-130<\/strong><\/a>, <a href=\"https:\/\/globecore.com\/products\/zeolite-oil-drying-units\/zp-sorbent-cartridges\/\"><strong>ZP-260<\/strong><\/a>) sont souvent utilis\u00e9es. Gr\u00e2ce \u00e0 leur structure microporeuse, elles adsorbent l\u2019eau et permettent une d\u00e9shydratation pouss\u00e9e sans chauffage. Ces cartouches peuvent \u00eatre facilement remplac\u00e9es et r\u00e9g\u00e9n\u00e9r\u00e9es \u00e0 l\u2019aide d\u2019une unit\u00e9 <a href=\"https:\/\/globecore.com\/products\/zeolite-regeneration-and-drying\/brps-zeolite-regeneration-block\/\"><strong>BRPS<\/strong><\/a>, ce qui les rend particuli\u00e8rement pratiques pour les interventions mobiles ou d\u2019urgence.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Lorsque l\u2019huile est fortement contamin\u00e9e et que sa teneur en eau atteint 50 % ou davantage \u00e0 la suite d\u2019une inondation ou de conditions de stockage inad\u00e9quates, les unit\u00e9s de coalescence de type <a href=\"https:\/\/globecore.com\/products\/oil-filtration-pumping\/cmm-1cf\/\"><strong>CMM-CF<\/strong><\/a> constituent la solution la plus appropri\u00e9e. Leur principe de fonctionnement repose sur la coalescence : les gouttelettes microscopiques d\u2019eau fusionnent pour former des gouttes plus volumineuses lorsque l\u2019huile traverse des \u00e9l\u00e9ments filtrants sp\u00e9ciaux, ce qui permet leur s\u00e9paration m\u00eame en cas de contamination importante. Ces syst\u00e8mes sont particuli\u00e8rement utiles dans les situations d\u2019urgence, car ils permettent de r\u00e9cup\u00e9rer des huiles qui devraient autrement \u00eatre \u00e9limin\u00e9es. Ils sont \u00e9galement compatibles avec le gazole, le k\u00e9ros\u00e8ne et les huiles de transformateur.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">La contamination par l\u2019eau acc\u00e9l\u00e8re consid\u00e9rablement le vieillissement de l\u2019huile et la d\u00e9gradation de l\u2019isolation, mena\u00e7ant directement la dur\u00e9e de vie des transformateurs. Les technologies avanc\u00e9es de d\u00e9shydratation de l\u2019huile, telles que le s\u00e9chage thermique sous vide, l\u2019adsorption par z\u00e9olithe et la coalescence, offrent des solutions efficaces pour \u00e9liminer l\u2019eau libre, dissoute et \u00e9mulsionn\u00e9e. <\/span><\/p>\n<p style=\"text-align: justify;\">\n","protected":false},"excerpt":{"rendered":"<p>La d\u00e9shydratation de l\u2019huile est l\u2019un des processus les plus importants pour garantir le fonctionnement fiable des transformateurs de puissance, qui comptent parmi les composants les plus co\u00fbteux de l\u2019ensemble du syst\u00e8me d\u2019alimentation \u00e9lectrique. Toute d\u00e9faillance de ces \u00e9quipements peut entra\u00eener de graves perturbations de l\u2019approvisionnement en \u00e9nergie et des pertes financi\u00e8res importantes pour les<a class=\"cg-read-more\" href=\"https:\/\/globecore.com\/fr\/oil-maintenance-fr\/oil-dewatering-in-power-transformers\/\" target=\"_blank\">Read More <\/a><\/p>\n","protected":false},"author":7,"featured_media":352729,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_themeisle_gutenberg_block_has_review":false,"_wpml_language_code":"","footnotes":""},"categories":[1339],"tags":[],"class_list":["post-352728","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-oil-maintenance-fr","oil_type-carburant-diesel","oil_type-esters-naturels","oil_type-fluide-dielectrique-midel-7131","oil_type-fluide-ignifuge-fyrquel","oil_type-huile-de-silicone","oil_type-huile-de-transmission","oil_type-huile-hydraulique","oil_type-huile-industrielle","oil_type-huile-pour-cables","oil_type-huile-pour-compresseur","oil_type-huile-pour-transformateur","oil_type-huile-pour-turbine","oil_type-huile-shell-diala","process_type-deshydratation"],"acf":[],"language":"fr","_links":{"self":[{"href":"https:\/\/globecore.com\/fr\/wp-json\/wp\/v2\/posts\/352728","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/globecore.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/globecore.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/globecore.com\/fr\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/globecore.com\/fr\/wp-json\/wp\/v2\/comments?post=352728"}],"version-history":[{"count":1,"href":"https:\/\/globecore.com\/fr\/wp-json\/wp\/v2\/posts\/352728\/revisions"}],"predecessor-version":[{"id":352730,"href":"https:\/\/globecore.com\/fr\/wp-json\/wp\/v2\/posts\/352728\/revisions\/352730"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/globecore.com\/fr\/wp-json\/wp\/v2\/media\/352729"}],"wp:attachment":[{"href":"https:\/\/globecore.com\/fr\/wp-json\/wp\/v2\/media?parent=352728"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/globecore.com\/fr\/wp-json\/wp\/v2\/categories?post=352728"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/globecore.com\/fr\/wp-json\/wp\/v2\/tags?post=352728"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}