What is DGA analysis and how to ensure it reflects true faults?
- This topic has 1 reply, 2 voices, and was last updated 3 months ago by .
Answers
-
September 15, 2025 at 7:28 am by Christopher Hansen
DGA identifies gases from partial discharge, overheating, or arcing. If oil contains dissolved atmospheric gases or water, results become unreliable. GlobeCore’s oil degassing units eliminate this risk and ensure precision.