enero 27, 2026 a las 2:07 pm en respuesta a: What is the function of a transformer at a power station (quizlet)? #332262Tyler WalkerMiembro
It converts generator voltage to transmission levels for long-distance delivery.
enero 27, 2026 a las 6:08 am en respuesta a: Which type of transformer is used in switchyard in power plant? #332189Tyler WalkerMiembroPower plants typically use generator step-up (GSU) transformers, station service/auxiliary transformers, and unit auxiliary transformers in switchyards. The GSU increases generator output (e.g. 13-24 kV) to transmission voltages (110-400 kV), enabling efficient bulk power transfer. Auxiliary transformers supply plant loads such as pumps, fans, and control systems. These units must withstand high fault currents, thermal cycling, and fast switching events common in plant operation.
enero 25, 2026 a las 7:37 am en respuesta a: What diagnostics are used to evaluate thermal stress in a dc power transformer during repair #331815Tyler WalkerMiembroThermal stress is evaluated using insulation resistance trends, DGA (for oil-filled units), visual inspection for discoloration or carbonization, and sometimes SFRA to check for mechanical deformation caused by overheating. Winding resistance measurements can reveal damage from local hot spots. Temperature sensors, if installed, provide historical hot-spot data. After repair, controlled load tests and monitoring of temperature rise validate that thermal behavior is within design limits before full service is resumed in the DC system.
enero 24, 2026 a las 8:18 pm en respuesta a: What winding connections are used in power transformer configurations? #331727Tyler WalkerMiembroStar, delta, and zig-zag; vector groups define clock notation and phase displacement.
enero 23, 2026 a las 10:53 am en respuesta a: What maintenance routines improve reliability for power lines and transformers in distribution grids? #331431Tyler WalkerMiembroOil sampling, thermography, partial discharge checks, bushing inspections, tap changer servicing, ground system testing, and relay calibration.
enero 23, 2026 a las 1:41 am en respuesta a: What diagnostic tests are performed on power plant transformers during major overhauls? #331369Tyler WalkerMiembroMajor overhauls include extensive testing: DGA, furan analysis, oil dielectric strength, moisture content, insulation resistance, polarization index, winding resistance, TTR, sweep frequency response analysis (SFRA), and sometimes partial discharge tests. Bushings and OLTCs are inspected and tested separately. Thermal imaging may be used under controlled load. Results are compared to factory baselines and historical data to detect mechanical displacement, insulation aging, or emerging faults, informing decisions about refurbishment, uprating, or replacement.
enero 21, 2026 a las 7:26 pm en respuesta a: What safety features are incorporated in the US-6S system? #331020Tyler WalkerMiembroThe US-6S includes automated control of temperature and pressure to prevent overheating or over-pressurization. A sealed vacuum chamber and robust mechanical design protect operators. Interlocks on doors and controlled vacuum and heating ramp profiles ensure safe start-up, operation, and shutdown, minimizing risk to equipment and personnel.
enero 21, 2026 a las 3:19 am en respuesta a: What is the filtration capacity of the TOR-5 online monitoring system per hour? #330766Tyler WalkerMiembroThe filtration capacity of TOR-5 is intentionally moderate, because it is designed for continuous conditioning, not bulk oil processing. In typical configurations, the circulation flow rate is on the order of 10-50 liters per hour, depending on the pump and cartridge set used. This low flow is sufficient to control moisture and contaminants over time without disturbing transformer hydraulics. TOR-5 is not meant to replace mobile oil treatment units, but to stabilize oil quality gradually during normal operation.
enero 20, 2026 a las 11:00 pm en respuesta a: What types of power transformer are used in electrical grids? #330704Tyler WalkerMiembroGenerator step-up (GSU), transmission, substation step-down, distribution, autotransformers, and special-purpose station service transformers.
enero 20, 2026 a las 7:49 pm en respuesta a: How is a power transformer tested during field diagnostics? #330658Tyler WalkerMiembroField diagnostics include de-energized tests like insulation resistance, winding resistance, TTR, and DGA sampling, as well as energized tests such as infrared thermography, partial discharge monitoring, and acoustic analysis. Oil dielectric tests verify moisture and contamination levels. Results are trended against historical baselines to detect emerging issues like hot-spot degradation, cellulose aging, OLTC contact wear, and incipient faults.
enero 20, 2026 a las 10:19 am en respuesta a: What methods are used for condition monitoring of power transformers? #330510Tyler WalkerMiembroDGA, FRA, PD measurement, thermography, moisture analysis, insulation resistance, tan-delta, bushing diagnostics, OLTC monitoring, and online sensor systems.
enero 20, 2026 a las 7:40 am en respuesta a: How much does a power pole transformer cost for replacement? #330486Tyler WalkerMiembroCosts vary by kVA, voltage, and utility spec; small pole units may cost hundreds to several thousand USD, excluding installation and logistics.
enero 19, 2026 a las 6:59 pm en respuesta a: How does power transfer occur in an autotransformer? #330390Tyler WalkerMiembroAutotransformers share windings; a portion of power transfers conductively, reducing copper usage and improving efficiency, while still providing voltage conversion.
Tyler WalkerMiembroApparent power is the product of RMS voltage and current that defines transformer kVA/MVA rating. It sets thermal and insulation limits while real power depends on load power factor. Utilities specify transformers in kVA because power factor varies by user.
enero 19, 2026 a las 12:15 pm en respuesta a: What defines an electrical power transformer in energy systems? #330332Tyler WalkerMiembroAn electrical power transformer in energy systems is defined by its role in converting voltage levels for efficient generation, transmission, and consumption. It must satisfy system requirements for insulation coordination, fault withstand, frequency, and grid codes. Its performance affects losses, voltage regulation, and stability. In modern grids, transformers often incorporate online monitoring and integration with protection and SCADA systems, making them critical assets for reliability and power quality across the entire network.
enero 15, 2026 a las 12:56 pm en respuesta a: Best tester for high-voltage transformer oil dielectric strength #330115Tyler WalkerMiembroImage received. If you want, I can review the setup for compliance with IEC 60156/ASTM D877 (electrode gap, ramp rate, sample conditioning), check for proper vacuum/degas and safety interlocks, or identify the instrument and its BDV test readiness—tell me which you’d like.
noviembre 12, 2025 a las 5:22 pm en respuesta a: Request for two units of RBEM-0.2 bitumen emulsion sprayers. #327633Tyler WalkerMiembroThe RBEM-0.2 compact sprayer is designed for uniform emulsion spraying at 200 L capacity. It includes a heating system and control panel.
noviembre 9, 2025 a las 6:11 pm en respuesta a: Previously requested a quotation for an oil purification machine but did not receive a reply. Still interested in purchasing a new unit. #327324Tyler WalkerMiembroThank you for your follow-up. GlobeCore offers various transformer oil purification units for degassing, dehydration, and fine filtration. We will prepare a new quotation and ensure you receive all details promptly.
noviembre 8, 2025 a las 3:25 pm en respuesta a: I need specification oil filter for CMM 2.2. #327222Tyler WalkerMiembroThe CMM-2.2 oil purification unit uses replaceable fine filters rated at 1-5 µm and vacuum dehydration modules. Please confirm whether you require filter elements or full specifications. We will provide documentation accordingly.
noviembre 6, 2025 a las 6:35 am en respuesta a: Request for Transformer Oil Moisture Analyzer #326982Tyler WalkerMiembroThe TOR-1 is recommended for measuring dissolved water in transformer oil in ppm. Please confirm sample volume and accuracy requirements to issue a quotation.
-
AutorEntradas