  • en respuesta a: How to calculate the power of a transformer? #332315
    Olivia Baker
    Participante

    Apparent power rating: S = V × I (1-phase) or S = ?3 × V × I (3-phase). Used to size MVA ratings for transmission and industrial applications.

    en respuesta a: what is a power distribution transformer? #332151
    Olivia Baker
    Participante

    A power distribution transformer is used to step down medium voltage (for example, 11-33 kV) to low voltage levels suitable for end users, such as 400/230 V in many systems. It is installed on poles, pads or inside kiosks near load centers. Distribution transformers are designed for high efficiency at light to medium loads since they are energized continuously and often lightly loaded. They typically have fixed or limited tap ranges, simple protection and focus on robustness, low no load losses and minimal maintenance in everyday service.

    en respuesta a: in a transformer how does the power input to the primary? #331977
    Olivia Baker
    Participante

    Power enters the primary winding as AC electrical energy. The alternating current produces a changing magnetic flux in the core, which induces voltage in the secondary winding. Energy transfer occurs magnetically rather than by direct conduction. In an ideal transformer, primary power equals secondary power. In real transformers, core and copper losses reduce delivered power.

    Olivia Baker
    Participante

    Utility designs reflect grid code requirements, contingency loading, maintenance philosophy, remote monitoring, and interoperability with protection and SCADA systems.

    Olivia Baker
    Participante

    Utilities evaluate technical compliance with IEC/IEEE standards, proven reliability, loss performance, total cost of ownership, manufacturing capacity, and delivery time. They assess service support, spare parts availability, testing facilities, and previous project performance. Quality certifications, warranty terms, and experience with similar voltage and MVA classes are critical. Environmental and safety practices, including oil containment and fire behavior, also influence supplier selection, alongside commercial factors like price and financing options.

    en respuesta a: Which industries use international power transformers? #331061
    Olivia Baker
    Participante

    International-spec power transformers are used wherever equipment or projects span multiple grid standards: global EPC projects, export-oriented manufacturing, offshore platforms, shipping, cross-border interconnectors, and multinational industrial groups. These transformers are designed to comply with IEC/IEEE and various regional codes, enabling deployment in Africa, Middle East, Asia, Europe, and the Americas without major redesign, thus serving diverse industrial and utility customers worldwide.

    en respuesta a: Who are major power transformer manufacturers in China? #330924
    Olivia Baker
    Participante

    In China, several large state-owned and private enterprises produce HV/EHV power transformers, autotransformers, and HVDC converter transformers. They serve State Grid, Southern Grid, railways, and export markets. These companies operate large-scale factories with UHV testing capability, supplying 110-1100 kV class transformers, as well as medium-power and distribution units. Exact rankings shift over time, so market overviews usually refer to them collectively as «leading Chinese transformer OEMs.»

    Olivia Baker
    Participante

    Hammond Power Solutions transformers are often used in heavy duty industrial sectors such as metal processing, mining, automotive manufacturing, chemical plants and large HVAC systems. They also serve data centers, oil and gas, renewable projects and commercial buildings that need robust dry type or liquid filled units. Their control and isolation transformers are common in motor control centers and automation panels. Customers value rugged construction, multiple voltage options and compliance with North American safety standards.

    Olivia Baker
    Participante

    For mineral transformer oil in a vacuum dehydration/degassing unit, heater setpoints are usually kept in a moderate band: enough to drop viscosity and speed mass transfer, but not so high that you accelerate oxidation or «stray gassing.» Many service practices run around 60-70 °C for efficient vacuum drying/degassing, while CIGRE guidance also notes that oil treatment can be effective even at ~40-50 °C if the vacuum and process are set correctly. In the field, a common rule is don’t push much above ~65 °C unless you have a specific reason and tight control, because higher temperature increases aging rate.

    Olivia Baker
    Participante

    There is no single fixed drying time for a 5 MVA transformer in a vacuum oven, because it depends strongly on initial moisture content, insulation thickness, and the applied temperature and vacuum level. In practice, for a mid-size 5 MVA unit, a typical drying cycle ranges from 48 to 120 hours. Well-prepared transformers with moderate moisture may be dried in 2-3 days, while heavily wetted insulation can require 5 days or more. The end point is defined by moisture evolution rate and insulation resistance, not by time alone.

    Olivia Baker
    Participante

    Applied/induced voltage tests, partial discharge, impulse tests, and oil dielectric breakdown testing validate insulation margins.

    Olivia Baker
    Participante

    132/33 kV transformers are used to step down transmission voltages for distribution feeders supplying cities, industrial clusters, and commercial loads.

    Olivia Baker
    Participante

    Thank you for your inquiry. GlobeCore provides transformer oil regeneration units (CMM-R series) for purchase and rental depending on availability. Please specify rental period, oil volume, and transformer capacity, and we will confirm options and delivery to Palota, Romania.

    Olivia Baker
    Participante

    GlobeCore provides complete systems for oil regeneration, purification, and testing, including CMM-R (regeneration), CMM (purification), and TOR (testing) series. Please share the scope of supply required to prepare an RFQ response.

    en respuesta a: Can I use one oil purifier for multiple types of oil? #324985
    Olivia Baker
    Participante

    Yes, GlobeCore machines are built to handle transformer, hydraulic, turbine, and compressor oils with minimal setup change. Their systems offer customizable filtration stages and temperature settings for optimal purification of each fluid type.

    en respuesta a: ¿Qué hace una desgasificadora de aceite dieléctrico? #324932
    Olivia Baker
    Participante

    Elimina gases disueltos en el aceite que pueden generar descargas internas en los transformadores. GlobeCore fabrica desgasificadoras con múltiples etapas de vacío, calentamiento preciso y sensores de gas en línea.

    en respuesta a: What are the advantages of GlobeCore oil filtration systems? #324832
    Olivia Baker
    Participante

    GlobeCore oil filtration systems offer modular design, stainless steel internals, automated safety controls, and international compliance (IEC, CE). Whether for transformer, hydraulic, or turbine oil, they provide reliable purification with low operating costs.

    en respuesta a: What is jet engine oil and why is maintenance important? #323712
    Olivia Baker
    Participante

    Jet engine oil is a synthetic or ester-based lubricant designed to withstand high temperatures and oxidation in aviation turbines. GlobeCore filtration units degas and clean these oils, ensuring reliability and preventing premature degradation.

    en respuesta a: What is Type II mineral oil and how is it different? #323618
    Olivia Baker
    Participante

    Type II mineral oil is an inhibited insulating fluid with additives to slow oxidation and acid formation. GlobeCore purification units maintain these oils by removing contaminants while preserving the inhibitors’ effectiveness.

    en respuesta a: Why use insulating mineral oil and how is it treated? #323240
    Olivia Baker
    Participante

    Insulating mineral oil is a refined petroleum product valued for its cooling properties and electrical insulation in transformers. GlobeCore systems remove water, gases, and sludge from mineral oils, maintaining performance and preventing breakdowns.