Why does the breakdown voltage of transformer oil decrease over time?
- Este tópico contém 1 resposta, 2 utilizadores e foi actualizado pela última vez há 7 meses, 3 semanas por Ahmed Abdullah.
Answers
-
Setembro 11, 2024 às 2:29 am by Ahmed Abdullah
The breakdown voltage of transformer oil decreases over time due to several factors that affect its insulating properties. Firstly, the presence of moisture in the oil can significantly reduce its breakdown voltage, as water acts as a conductive medium that facilitates electrical discharge. Additionally, the accumulation of particulates and contaminants, such as dirt and wear debris, can create conductive paths within the oil, further lowering its breakdown voltage. Oxidation of the oil occurs when it is exposed to heat and air, leading to the formation of acidic compounds and sludge, which impairs its insulating capabilities. Moreover, the thermal degradation of oil components can alter its molecular structure, diminishing its effectiveness as an insulator. Regular testing with Globecore oil testers is essential to monitor these changes and ensure the reliability and safety of transformers. Therefore, understanding why does transformer oil breakdown voltage reduce is crucial for maintaining optimal transformer performance and longevity.
Articles by Topic
- Electric oven transformers online drying system CMM-260C
- Marine transformers online drying system CMM-260C
- Mining power transformers online drying system CMM-260C
- Participación en el Seminario Internacional “Pruebas Eléctricas a Transformadores, LTC´s y Técnicas de Diagnóstico al Fluido Aislante”
- Participation in the International Seminar on Electrical Testing of Transformers, LTCs, and Diagnostic Techniques for Insulating Fluids
- Traction transformers online drying system CMM-260C
- Power transformers online drying machine at electric power plants system CMM-260C
- Network distribution online transformers drying system CMM-260C
- Fuel addition injection block USB-6
- Transformer oil antioxidant additives injection block USB-6
- Oils antifoaming addition agents injection block USB-6
- Diesel fuel drying machine ZP-260
- Heating fuel drying machine ZP-260
- Network distribution transformers monitoring system TOR-5
- Power transformers monitoring machine at electric power plants TOR-5
- Traction transformers monitoring system TOR-5
- Mining power transformers monitoring system TOR-5
- Marine transformers monitoring system TOR-5
- Electric oven transformers monitoring system TOR-5
- Step-up transformers monitoring system in wind power plants TOR-5
- Oil and gas industry transformers monitoring system TOR-5
- Airports transformers monitoring system TOR-5
- Medical transformers monitoring system TOR-5
- Railway transformers monitoring system TOR-5
- Subway transformers monitoring system TOR-5
- Seaport transformers monitoring system TOR-5
- Water treatment plants transformers monitoring system TOR-5
- Chemical factories transformers monitoring system TOR-5
- Large sports arenas lighting transformers monitoring system TOR-5
- Traffic control systems transformers monitoring system TOR-5
- Hospitals transformers monitoring system TOR-5
- Data centers transformers monitoring system TOR-5
- Military bases transformers monitoring system TOR-5
- Telecommunication towers transformers monitoring system TOR-5
- Banks transformers monitoring system TOR-5
Only registered users can answer. No account? Sign up!
GlobeCore Related Posts
Un representante de GlobeCore participó en el Congreso de Ingenieros del Estado de Veracruz (México)
Obras de producción y suministro de equipos completadas, para las necesidades de la industria minera
Globecore e Apfelbaum anunciam apresentação conjunta no 5º seminário anual WEIDMANN / PROLEC-GE 2014