  • em resposta a: What is gear oil purification and why is it important? #121411

    Gear oil purification is the process of removing contaminants such as dirt, water, metal particles, and oxidation products from gear oil used in machinery. This purification restores the oil’s original properties, like viscosity and lubricity, ensuring optimal performance. It is important because contaminated gear oil can lead to increased friction, wear, and overheating of gear systems, ultimately causing equipment failure. Regular purification extends the lifespan of both the oil and the machinery, reduces maintenance costs, and enhances operational efficiency.

    em resposta a: How do you test an A/C transformer? #119926

    To test an A/C transformer, you will need a multimeter to measure the voltage and resistance across the primary and secondary windings. First, ensure the power is disconnected to avoid electrical shock. Set your multimeter to measure AC voltage and check the voltage on the primary side to see if it matches the specified input for your transformer. Then, measure the secondary side to verify it produces the correct output voltage. Additionally, switch your multimeter to the resistance setting to check for continuity in the windings; this will help identify any short circuits or open circuits within the transformer. If you suspect that the insulation is compromised, consider using a Megger insulation tester to check the transformer windings for insulation resistance, ensuring they provide adequate protection against electrical faults. Properly assessing the condition of the transformer will determine if it’s functioning correctly or needs replacement. Remember, when testing industrial oils and their related equipment like transformers, using specific testers like the ones provided by Globecore can ensure accuracy and reliability in diagnostics.

    em resposta a: Who are the prominent potassium humate fertilizer manufacturers? #119717

    Prominent potassium humate fertilizer manufacturers include:
    Shandong Chuangxin Humic Acid Technology Co., Ltd. (China) – A leader in humic acid and potassium humate products.
    AGROPOWER S.A. (Ukraine) – Known for its advanced potassium humate fertilizers for large-scale agricultural use.
    Humic Growth Solutions (USA) – Specializes in liquid and granular humic acid and potassium humate formulations for agriculture.
    Nutri-Tech Solutions (Australia) – Focuses on sustainable agriculture and humic acid-based fertilizers.
    These manufacturers are known for producing high-quality, water-soluble potassium humate fertilizers that improve crop yields and soil health.

    em resposta a: How is the breakdown voltage of oil measured? #119113

    The breakdown voltage of oil is measured using a specific device, often referred to as a dielectric strength tester, which applies voltage to a sample of the oil until insulation failure occurs. The Globecore oil breakdown voltage tester is designed to accurately assess the dielectric properties of industrial oils. This tester employs electrodes placed in the oil sample, gradually increasing the voltage until the oil breaks down, providing a clear measurement of the breakdown voltage. The results are crucial for determining the oil’s insulation quality and overall effectiveness in electrical applications.

    em resposta a: What is the difference between Hi-Pot and BDV testing? #118823

    The primary difference between Hi-Pot testing and BDV testing lies in their specific applications and measuring methods. Hi-Pot testing, also known as high potential testing, is primarily used to assess the insulation strength of electrical equipment by applying a high voltage to determine if there are any breakdowns or leaks. In contrast, BDV testing refers to Breakdown Voltage testing, which specifically measures the voltage at which an insulating oil begins to conduct electricity, indicating its dielectric strength. BDV testers, like those offered by Globecore, are designed to provide accurate and reliable readings of the breakdown voltage of industrial oils, ensuring their quality and effectiveness in electrical applications. Both of these testing methods are critical in ensuring the safety and reliability of electrical systems, but they focus on different aspects of electrical insulation. When it comes to selecting the right tester for your needs, understanding the specific differences between Hi-Pot and BDV testing can guide you in choosing a suitable device from Globecore’s lineup, helping you maintain optimal performance in your operations with a bdv tester megger.

    em resposta a: What can cause an oil-filled transformer explosion? #118659

    An oil-filled transformer explosion can be caused by several factors, including electrical failures such as short circuits or overloads that generate excessive heat, leading to the breakdown of insulation materials; the accumulation of flammable gases from oil degradation or overheating; external impacts such as lightning strikes or vandalism; and inadequate maintenance that fails to monitor oil levels and prevent moisture ingress, which compromises the transformer’s functionality. Additionally, poor ventilation can exacerbate heat build-up, increasing the risk of ignition. Proper understanding of the oil filled transformer diagram can aid in identifying critical components that should be regularly inspected to prevent these failures.

    em resposta a: What does the interfacial tension test of transformer oil show? #118458

    The interfacial tension test transformer oil is a crucial assessment that measures the oil’s ability to maintain its insulating properties and contaminate resistance. It indicates the presence of polar compounds, which can arise from oxidation, hydrolysis, or contamination. A decrease in interfacial tension suggests degradation of the oil, leading to increased risk of failures in electrical equipment due to the loss of insulating capability. Regular testing helps determine the oil’s condition, predict its lifespan, and ensure the reliability of transformer operations.

    em resposta a: How often should transformer oil be tested? #118394

    Transformer oil should typically be tested at least once a year as part of a routine maintenance program. However, the testing frequency may vary based on the transformer’s operational conditions, age, and any abnormalities observed. It’s essential to monitor oil quality consistently to prevent breakdown and ensure optimal performance. Regular testing helps identify any issues like moisture, dissolved gases, and acidity that could impact the transformer’s efficiency and longevity.

    em resposta a: What does FM-approved transformer oil mean? #118337

    FM-approved transformer oil refers to insulation oil that has received certification from Factory Mutual (FM) Global, indicating that it meets specific fire safety and performance standards essential in electrical equipment applications. This type of transformer oil is designed to provide effective insulation, cooling, and fire suppression properties, minimizing risk in case of electrical faults. Utilizing FM-approved transformer oil ensures compliance with industry safety regulations and enhances the reliability and safety of transformer operations, making it a preferred choice for various electrical installations.

    em resposta a: What does the presence of ethane in transformer oil indicate? #118300

    The presence of ethane in transformer oil typically indicates the occurrence of thermal decomposition or electrical discharges within the transformer. When temperatures rise beyond normal operating levels or when arcing occurs, hydrocarbons in the oil can break down, leading to the formation of light hydrocarbons such as ethane. Therefore, detecting ethane in transformer oil may signify potential issues such as insulation failure or overheating, necessitating further analysis and possible maintenance to ensure the safe operation of the transformer. Regular monitoring of ethane levels in transformer oil is crucial for preventive maintenance and the overall longevity of the equipment.

    If an electrical transformer is leaking oil, immediate action is essential to prevent environmental contamination and maintain operational integrity. First, identify the source of the leak by inspecting seals, gaskets, and joints. Once located, assess the severity of the leak and determine if the transformer can continue operating safely. If the leak is significant, consider shutting down the transformer to avoid further oil loss, which could lead to overheating or electrical failures. Ensure proper containment measures are in place to capture any leaking oil, and use absorbent materials if necessary. Notify relevant personnel and follow your facility’s protocols for hazardous materials. Depending on the leak’s severity, arrange for oil regeneration and cleaning or replacement if needed. It’s crucial to conduct regular maintenance checks on electrical transformers to prevent future leaks and to ensure compliance with environmental regulations.

    em resposta a: Where can transformer oil be purchased? #117708

    Transformer oil can be purchased from specialized oil suppliers, electrical equipment manufacturers, large industrial supply companies, online platforms, and local distributors. It’s important to ensure that the product meets the required specifications.

    em resposta a: What is an oil furnace transformer? #117117

    An oil furnace transformer is a device that converts low voltage to high voltage, typically to power the ignition system of an oil furnace. It generates the necessary spark to ignite the oil, allowing the furnace to produce heat efficiently.