GlobeCore

  • Home
  • Products
    • Oil Regeneration
      • CMM-6RL Oil Regeneration Unit
      • CMM-10RL Transformer Oil Regeneration Plant
      • CMM-12R Oil Regeneration Systems
      • CMM-12R Oil Regeneration System (With Activated Bauxite)
      • CMM-8RSL/4000 Transformer Oil Regeneration Plant (With Fuller’s Earth)
      • USB-6 Oxidation Inhibitor injection unit
      • СММ-0,001U Laboratory Oil Filtration Unit
    • Oil Purification & Degassing Machines
      • CMM-0.6L Oil Degassing & Filtration Cart
      • СММur-1L mobile oil plant
      • CMM-1.0LT Transformer Oil Purification Unit
      • CMM-1H Oil Processing Unit
      • CMM-2.2LT Industrial Oil Purification Unit
      • CMM-4,0T Turbine oil filtration
      • CMM-4,0LT Transformer Oil Purification Unit
      • CMM-4/7 portable oil degassing unit
      • CMM-6LT Industrial Oil Purification Unit
      • CMM-6/7 Degassing Unit
      • CMM-8LT Oil Processing Unit
      • CMM-10 — Transformer Oil Purification Machine
      • CMM-15 Oil Degassing Plant
    • Oil Filtration Machines
      • CMM-1,0CF Unit for Removal of Water from Oil
      • CMM-2,0CF Unit for Removal of Water from Oil
      • CMM-1,2Fr Industrial oils filtration unit with self-cleaning filters
      • CMM-4,0F Oil filtration unit
    • Oil Drying Unit
      • ZP-130 Sorbent Cartridges
      • ZP-260 Sorbent Cartridges
    • Oil Heating
      • PPM Inline Oil Heater. Stream oil heating
    • Fuel Polishing
      • TOR-1 diesel fuel moisture content tester
      • CMM-6RL dark diesel fuel polishing machine
      • CMM-6RL dark heating fuel polishing machine
      • CMM-6RL low-viscosity marine fuel polishing machine
    • Online Transformer Dry-Out Systems
      • CMM-260C Online Transformer Dry-Out System
      • TOR-4 Online Transformer Dry-Out System
    • Online Transformer Monitoring Systems
      • TOR-5 Online Transformer Monitoring System
    • Transformer Maintenance
      • Mojave Heat (Sukhovey): Hot Air Dryer Unit
      • UVV Vacuum Cold Trap
      • US-6S Transformer vacuum furnace
      • LFD Low Frequency Heating Device
      • BV-3000 Transformer Evacuation System
      • BV-5000 Transformer Evacuation System
      • UVD Vacuum Oil Filling Unit
      • UVD-1000 Oil Filling and Transportation System
      • TSS Transformer Safety System
      • CMM-6RL Oil Regeneration Unit
      • CMM-10RL Transformer Oil Regeneration Plant
      • CMM-12R Oil Regeneration Systems
    • Vacuum Transformer Drying Ovens
      • US-6S Transformer vacuum furnace
    • Sorbent Processing
      • ZP-130 Sorbent Cartridges
      • ZP-260 Sorbent Cartridges
    • Instruments – Transformer Oil Testers
      • TOR-1 Oil Moisture Meter
      • TOR-2 Hydrogen and Moisture Analyzer for Transformer Oil Monitoring
      • TOR-3 (TOR-3 SL) Oil Tan Delta Tester
      • TOR-6 Transformer Oil Moisture and Particles Tester
      • TOR-7 Universal Transformer Oil Tester (moisture, gases, solid particles)
      • TOR-8 tester for residual gas content of insulating oil
      • TOR-60 (TOR-60 SL) Breakdown Voltage Tester
      • TOR-80 (TOR-80 LSL) Breakdown Voltage Tester
      • TOR-80A (TOR-80 ASL) Transformer Oils Breakdown Voltage Tester with Battery
      • TOR-100 (TOR-100 SL) Breakdown Voltage Tester
    • Wind Turbine Service
      • CMM-G wind turbine gearbox oil changer (with dimensions adapted to the customer’s trailer ones)
      • CMM-G Wind Turbine Gearbox Oil Changer
      • CMM-GL Wind Turbine Gearbox Oil Changer
      • CMM-0.6L Oil Degassing & Filtration Cart
      • CMM-4,0T Turbine oil filtration
    • Medical Equipment Maintenance
      • CMM-0.6 X-ray Transformer Oil Purifier
      • AVSk-150 Hospital Wastewater Treatment Complex
    • Blending systems
      • USBL-1 Laboratory Blending System
      • USB-1 Fuel oil blending system
      • USB-5 high-speed mixing unit for production of sanitizers (0.15 – 0.3 m3/h)
      • USB-5 high-speed mixing unit for production of sanitizers (1.1 m3/cycle)
      • USB-6 Impeller Stirrer
      • Colloid Mill
      • Vortex Layer Devices
    • Colloid Mill
      • Colloid mills for food industry
        • CLM-100.3 Colloid mill
      • Colloid mills for bitumen emulsion production
        • CLM-0.25.1 Laboratory colloid mill
        • CLM-2/4 Colloid mill
        • CLM-16/25 Colloid mill
      • Colloid mills for bitumen modification
        • CLM-8/16 Colloid mill
        • CLM-10/20 Colloid mill
        • CLM-40.2 Colloid Mill
      • Colloid mills for different applications
        • CLM-100.2 Colloid Mill
        • CLM-200.2 Colloid Mill
    • Vortex Layer Devices
      • AVS-100 Mixing Machine. Vortex Layer Device
      • AVS-150 Chemical Mixing Machine
      • AVSp-100 Vortex Layer Device (Semi-Automated)
      • AVSp-150 vortex layer device (semi-automated)
      • AVSk-150 Wastewater Treatment Complex
    • Bitumen emulsion plant, Bitumen Emulsion Production
      • CLM-0.25.1 Laboratory colloid mill
      • USB-2 Bitumen emulsion unit 2 m3/hour production capacity
      • USB-2 Bitumen emulsion plant 8 m3/hour production capacity
      • FB Bitumen filter
      • USB-6 Impeller Stirrer
    • Bitumen Modification Plant. Modified Bitumen Production
      • USB-3 Bitumen modification laboratory system
      • USB-3 Continuous Bitumen Modification Unit (12 m3/hour)
      • USB-3 Bitumen modification unit 16 m3/hour production capacity
      • USB-4 Modified bitumen collection tank (USB-3)
      • USB-6 Impeller Stirrer
    • Laboratory system for Bitumen Emulsion Samples
      • CLM-0.25.1 Laboratory colloid mill
      • CLM-100.1 Bitumen Emulsion Laboratory System
      • USB-3 Bitumen modification laboratory system
    • Biodiesel Equipment
      • USB-1L Biodiesel laboratory equipment
      • USB-1 Biodiesel equipment
        • Filters
          • The filter GC Fine with a filtration factor β = 4000
        • Vacuum Pumps
          • GC Roots Vacuum Pumps
          • مضخات التفريغ GC Vane (مضخات دعم)
    • Custom Equipment
      • CMM-4R TRANSFORMER OIL REGENERATION MACHINE
      • CMM-1 MOBILE OIL PLANT
      • CMM-2.2 MOBILE OIL PLANT
      • CMM-4 MOBILE UNIT FOR POWERED TRANSFORMER OIL PROCESSING
      • CMM-12A DEGASSING UNIT
      • CMM-1CO CABLE OIL DEGASSING UNIT
      • CMM-5M INDUSTRIAL OIL PURIFICATION MACHINE
      • CMM-8RP Sorbent Reactivation Unit
      • BDK-3 CATALYTIC CONVERTER
      • CMM-600CF TRANSFORMER OIL FILTRATION AND REFILLING MACHINE
      • SN-1 PUMP ASSEMBLY
      • SBE-30 BITUMEN EMULSION COLLECTION TANK (UVB-1)
      • UVB-1 BITUMEN EMULSION UNIT 1 M3/HOUR PRODUCTION CAPACITY
      • UVB-1 EXTENSION 1 M3/HOUR PRODUCTION CAPACITY
      • INDUSTRIAL MIXER – COLLOID MILLS CLM-4 SMALL
      • BIG COLLOIDAL MILL CLM-18 GRINDING MACHINE
      • INDUSTRIAL MILL – GIANT COLLOIDAL MILL CLM-22
      • CMM-0.6 Clean Marine Oil Degassing Cart
      • Compressed Air Supply Unit UOV
    • Accessories & Components
  • Dealers
  • Tech School
    • Webinar Registration
  • News & Articles
  • History
  • Reviews
  • AskMe
  • Contacts
  • EN
    • FR
    • ES
    • PT
    • TH
    • VN
    • CN
    • HA
    • AZ
    • JP
    • DE
    • RO
    • Hun
    • Arabic
    • Ind
GlobeCore / Oil Processing / Transformers drying machine

Transformers drying machine

Effective transformers drying

Efficient Transformers Drying with the LFD Power Transformers Drying Machine by GlobeCore

In the realm of high-voltage equipment maintenance, transformers drying plays a critical role in ensuring optimal performance and prolonged service life. Moisture is a primary enemy of insulation systems in power transformers, causing electrical breakdowns, reducing dielectric strength, and accelerating aging. To combat this challenge, GlobeCore developed the LFD power transformers drying machine, a cutting-edge solution engineered to meet the most demanding industrial requirements.

Why Drying Transformers Is Essential

Moisture ingress in transformers can occur due to manufacturing processes, storage conditions, or long-term operation. Even a small amount of water can lead to:

  • Decreased dielectric strength of insulation oil
  • Formation of bubbles under high temperatures and loads
  • Accelerated aging of cellulose insulation
  • Increased risk of partial discharges and breakdowns

Traditional drying methods often involve removing the transformer from the site or using stationary ovens and vacuum chambers. These methods can be time-consuming, expensive, and impractical for on-site service. The modern approach is mobile, efficient, and capable of in-situ application — just like GlobeCore’s LFD drying unit.

Introducing the LFD Power Transformers Drying Machine

The LFD machine from GlobeCore is a high-performance, mobile drying system designed for both oil-filled and dry-type transformers. It operates on the principle of low-frequency heating (LFH), a revolutionary technology that heats the core and windings from the inside, drying the insulation thoroughly without dismantling the transformer.

Key Features:

  • Low-Frequency Heating Technology: Unlike traditional external heating, LFH creates uniform heating across the transformer windings and core, ensuring faster and deeper moisture removal.
  • Non-invasive Method: The transformer remains sealed during the drying process, eliminating the risk of additional moisture or contamination.
  • Energy Efficiency: LFH consumes significantly less power than conventional vacuum ovens or hot air systems.
  • Safe and Controlled Process: Integrated temperature sensors, power control, and monitoring systems provide full automation and safety during operation.
  • Portability: The LFD unit is designed for easy transportation, allowing drying of transformers directly at substations or industrial sites.

How It Works

The LFD drying machine uses a controllable low-frequency current that flows directly through the transformer windings. This current generates Joule heat (resistive heating), raising the temperature of the internal insulation. The heat drives out moisture from cellulose and other insulating components toward the surface, where it can be evacuated through vacuum systems or absorbed by desiccants.

The process typically includes the following steps:

  1. Connection to the Transformer: The unit connects to the transformer windings using safe, high-quality terminals.
  2. Controlled Heating: Low-frequency current is applied, heating the windings gradually.
  3. Moisture Removal: Water is extracted either under vacuum or with the help of auxiliary drying equipment.
  4. Monitoring and Control: Real-time sensors track temperature, moisture levels, and drying progress.
  5. Completion: Once moisture content reaches acceptable levels, the process is safely concluded.

Advantages of GlobeCore’s Transformers Drying Solution

The LFD unit offers several distinct advantages over traditional drying methods:

  • Faster Drying Time: Heating from the inside reduces drying time by up to 60%.
  • Improved Insulation Integrity: Uniform heating avoids hotspots and preserves the dielectric structure of materials.
  • Cost Savings: In-situ drying eliminates transport and disassembly costs.
  • Reduced Downtime: Quick setup and operation ensure minimal interruption of transformer service.
  • Environmental Safety: No need for oil drainage, minimizing risk of spills or contamination.

Applications of the LFD Drying Machine

GlobeCore’s LFD drying equipment is used worldwide in various sectors, including:

  • Power generation plants
  • Substations
  • Industrial enterprises
  • Transformer repair and service centers
  • Renewable energy facilities

Whether for routine maintenance, emergency repair, or transformer commissioning, the LFD machine is an indispensable tool for ensuring transformer reliability and longevity.

Power transformers drying machine at electric power plants LFD Sprcifications

№ Parameter Value
1 Maximum input current (AC), А 185
2 Maximum output current (sinusoidal AC), A 200
3 Automatically controlled AC output voltage, V 0-400
4 Ambient temperature, °C 0-40
5 Relative humidity, % There must be no
condensation
6 Output frequency, Hz 0.5-5
7 Ingress Protection Rating IP 54, IK 09
8 The power supply parameters Any options on
customer’s request
9 Dimensions, mm length 800
width 800
height 2000
10 Weight, kg 500

 

Technical Specifications

  • Heating Current: Low frequency (0.1–1.0 Hz), adjustable
  • Control System: Fully automated PLC with touch screen interface
  • Power Output: Customizable based on transformer size and rating
  • Temperature Monitoring: Multiple channels for precision control
  • Mobility: Mounted on a trailer or skid frame for field deployment

Why Choose GlobeCore?

With over 25 years of experience in transformer oil purification, regeneration, and service equipment, GlobeCore stands as a trusted global partner in electrical maintenance solutions. The LFD transformers drying machine is a testament to the company’s commitment to innovation, energy efficiency, and operational excellence.

GlobeCore machines are used in more than 100 countries, supported by local representatives and service centers. Each unit is manufactured to international standards, ensuring reliability, safety, and long service life.

Effective transformers drying is critical to maintaining the reliability and safety of electrical infrastructure. The LFD power transformers drying machine from GlobeCore represents a state-of-the-art solution that combines portability, speed, and deep insulation drying without the need for dismantling or transporting transformers. By investing in advanced LFH technology, industries can prevent costly failures, extend equipment lifespan, and ensure continuous power supply.

    Leave Your Request


    • Home
    • Products
    • Dealers
    • Tech School
    • Contacts

    ® Copyright by - 2025 © GlobeCore

    GlobeCore, Sadovskogo 14, Poltava, Ukraine, 36034

    This website uses cookies to improve your experience. By continuing to browse, you agree to our use of cookies. Read more in our Privacy Policy.