  • in reply to: Where to buy potassium humate for agricultural use? #119701
    Tyler Hill
    Member

    You can buy potassium humate for agricultural use from online marketplaces like Alibaba and Amazon, which offer various grades and types of potassium humate. Additionally, specialized agricultural suppliers and local fertilizer distributors often carry potassium humate products. Manufacturers like Humic Growth Solutions (USA) and Shandong Chuangxin (China) also sell potassium humate in bulk for agricultural purposes.

    Tyler Hill
    Member

    For bulk orders of soluble potassium humate, consider reaching out to established manufacturers such as:
    Shandong Chuangxin Humic Acid Technology Co. Ltd. (China): A leader in humic acid-based products, including potassium humate.
    AGROPOWER S.A. (Ukraine): Specializes in humic fertilizers and has a range of products including soluble potassium humate.
    Sunniland Corporation (USA): Offers soluble potassium humate products, particularly for the agricultural market.
    You can contact these companies directly or explore options through online platforms like Alibaba, which connects you with factories offering bulk orders of potassium humate.

    in reply to: How do you test an oil burner ignition transformer? #119371
    Tyler Hill
    Member

    To test an oil burner ignition transformer, first ensure safety by turning off power to the burner and confirming that there is no voltage present. Proceed to visually inspect the transformer for any signs of damage, such as burns or corrosion on the terminals. Next, use a multimeter to measure the secondary voltage; set the meter to the highest AC voltage setting and connect the leads to the transformer’s output terminals while the burner is activated. A typical transformer should output around 10,000 to 15,000 volts. If you find no output or low voltage, it may indicate a faulty transformer that requires replacement. Additionally, check the primary side of the transformer for proper voltage input to ensure that power is reaching the unit adequately. If everything checks out and the ignition system is still not functioning, other components may need examination. Always remember to follow safety precautions when handling electrical components in oil burner ignition systems. Proper maintenance and testing of equipment like the ignition transformer are crucial for the optimal functioning of oil burners. Testing oil burner ignition transformer functionality can prevent potential failures in the ignition process and ensure reliable operation.

    in reply to: How do you test a transformer on a furnace? #119329
    Tyler Hill
    Member

    To test a transformer on a furnace, first ensure that the power supply is turned off to eliminate any risk of electrocution. Next, use a multimeter, specifically a Globecore electric tester, to measure the voltage output of the transformer. Check the primary and secondary windings for continuity and ensure there are no short circuits. If the transformer has insulation, perform a high-pot test to assess the insulation integrity. Monitor the oil temperature if the transformer is oil-cooled to ensure it operates within safe limits. Additionally, utilize oil diagnostics provided by Globecore testers to analyze the condition of the transformer oil, checking for moisture and contamination which can affect performance. Regular testing and monitoring will help maintain the efficiency and longevity of your furnace transformer, ensuring optimal operation. Always refer to the manufacturer’s guidelines for specific testing procedures and safety protocols. Remember, the transformer health indirectly influences the furnace’s performance, so keep it well-maintained. Don’t overlook the significance of efficient testing methods to ensure safe operation, particularly around industrial machinery, where proper lubrication technologies, like oil analyzers, are vital as well. This comprehensive approach ensures that your transformer operates reliably and efficiently, reducing potential issues during furnace operation.

    in reply to: What is stray gassing in transformer oil? #119326
    Tyler Hill
    Member

    Stray gassing in transformer oil refers to the unintended generation of gases within the oil, which can compromise the performance and reliability of the transformer. This phenomenon typically results from the decomposition of the oil due to overheating, electrical discharges, or contamination. Stray gassing produces gases like hydrogen, methane, and ethylene, which can accumulate and lead to pressure build-up within the transformer, potentially causing insulation breakdown, reduced cooling efficiency, and even hazardous conditions if left unchecked. Monitoring for stray gassing is crucial for maintaining optimal transformer function, ensuring the longevity of the equipment, and preventing failures that could disrupt power supply systems. Regular analysis of transformer oil can help identify the presence of stray gassing and facilitate timely corrective actions. Proper cleaning, regeneration, and maintenance routines for transformer oil are essential to mitigate these risks effectively.

    in reply to: How is the dielectric breakdown voltage of oil tested? #119093
    Tyler Hill
    Member

    To determine the breakdown voltage of oil, Globecore offers various dielectric strength testers that work on the principle of applying a controlled voltage to a sample of the oil until an electrical discharge occurs. The tester typically involves placing a sample of oil in a test cell with two electrodes. The voltage is gradually increased, and the point at which the oil fails to insulate and allows current to pass through is recorded as the breakdown voltage. This measurement is critical as it indicates the oil’s ability to resist electrical failure, which is essential for ensuring the reliability of electrical insulation systems in industrial applications. This process ensures that the oil can effectively perform its function without causing equipment failure due to dielectric breakdown.

    in reply to: What is the expected dielectric strength of transformer oil? #118932
    Tyler Hill
    Member

    The dielectric strength of transformer oil is expected to be around 30 kV per centimeter (kV/cm) under normal operating conditions. However, this value can vary based on the oil’s purity, moisture content, and the presence of particles or contaminants. Regular testing with Globecore’s oil testers can help monitor and ensure that the dielectric strength remains within acceptable limits, which is crucial for the safe and efficient operation of transformers.

    in reply to: What is Chevron transformer oil used for? #117794
    Tyler Hill
    Member

    Chevron transformer oil is used for insulating and cooling transformers and other high-voltage electrical equipment. It provides excellent dielectric strength and thermal stability, ensuring reliable operation under various conditions. Chevron transformer oils are formulated to resist oxidation, maintain their insulating properties over time, and protect the transformer from moisture and contaminants.

    in reply to: How are transformer oil samples analyzed? #117716
    Tyler Hill
    Member

    Transformer oil samples are analyzed by collecting a sample from the transformer and performing a series of tests to assess the oil’s condition. Common analyses include:

    Dielectric Strength Test: Measures the oil’s ability to withstand electrical stress without breaking down.
    Dissolved Gas Analysis (DGA): Detects gases dissolved in the oil, which can indicate internal faults like arcing or overheating.
    Moisture Content Test: Determines the amount of water in the oil, as high moisture levels can reduce insulation effectiveness.
    Acidity Test: Assesses the oil’s acidity level, which can indicate oil degradation or contamination.
    Interfacial Tension (IFT) Test: Evaluates the surface tension between the oil and water, which can indicate contamination.

    in reply to: What is oil silicone used for in transformers? #117287
    Tyler Hill
    Member

    Silicone oil is used in transformers as an insulating and cooling fluid, particularly in applications requiring high thermal stability. Silicone oil is known for its ability to perform under extreme temperatures and harsh environmental conditions. It provides excellent electrical insulation, prevents overheating, and has a longer lifespan compared to traditional mineral oils, making it ideal for specific high-performance or high-temperature transformer applications.

    in reply to: What is an oil burner transformer? #117109
    Tyler Hill
    Member

    An oil burner transformer is a device that converts low voltage into high voltage, typically around 10,000 volts, to create a spark that ignites the oil in heating systems. It plays a crucial role in ensuring the efficient and reliable ignition of the fuel in oil burners.