GlobeCore

  • Home
  • Products
    • Oil Regeneration
      • CMM-6RL Oil Regeneration Unit
      • CMM-10RL Transformer Oil Regeneration Plant
      • CMM-12R Oil Regeneration Systems
      • CMM-12R Oil Regeneration System (With Activated Bauxite)
      • CMM-8RSL/4000 Transformer Oil Regeneration Plant (With Fuller’s Earth)
      • USB-6 Oxidation Inhibitor injection unit
      • СММ-0,001U Laboratory Oil Filtration Unit
    • Oil Purification & Degassing Machines
      • CMM-0.6L Oil Degassing & Filtration Cart
      • СММur-1L mobile oil plant
      • CMM-1.0LT Transformer Oil Purification Unit
      • CMM-1H Oil Processing Unit
      • CMM-2.2LT Industrial Oil Purification Unit
      • CMM-4,0T Turbine oil filtration
      • CMM-4,0LT Transformer Oil Purification Unit
      • CMM-4/7 portable oil degassing unit
      • CMM-6LT Industrial Oil Purification Unit
      • CMM-6/7 Degassing Unit
      • CMM-8LT Oil Processing Unit
      • CMM-10 — Transformer Oil Purification Machine
      • CMM-15 Oil Degassing Plant
    • Oil Filtration Machines
      • CMM-1,0CF Unit for Removal of Water from Oil
      • CMM-2,0CF Unit for Removal of Water from Oil
      • CMM-1,2Fr Industrial oils filtration unit with self-cleaning filters
      • CMM-4,0F Oil filtration unit
    • Oil Drying Unit
      • ZP-130 Sorbent Cartridges
      • ZP-260 Sorbent Cartridges
    • Oil Heating
      • PPM Inline Oil Heater. Stream oil heating
    • Fuel Polishing
      • TOR-1 diesel fuel moisture content tester
      • CMM-6RL dark diesel fuel polishing machine
      • CMM-6RL dark heating fuel polishing machine
      • CMM-6RL low-viscosity marine fuel polishing machine
    • Online Transformer Dry-Out Systems
      • CMM-260C Online Transformer Dry-Out System
      • TOR-4 Online Transformer Dry-Out System
    • Online Transformer Monitoring Systems
      • TOR-5 Online Transformer Monitoring System
    • Transformer Maintenance
      • Mojave Heat (Sukhovey): Hot Air Dryer Unit
      • UVV Vacuum Cold Trap
      • US-6S Transformer vacuum furnace
      • LFD Low Frequency Heating Device
      • BV-3000 Transformer Evacuation System
      • BV-5000 Transformer Evacuation System
      • UVD Vacuum Oil Filling Unit
      • UVD-1000 Oil Filling and Transportation System
      • TSS Transformer Safety System
      • CMM-6RL Oil Regeneration Unit
      • CMM-10RL Transformer Oil Regeneration Plant
      • CMM-12R Oil Regeneration Systems
    • Vacuum Transformer Drying Ovens
      • US-6S Transformer vacuum furnace
    • Sorbent Processing
      • ZP-130 Sorbent Cartridges
      • ZP-260 Sorbent Cartridges
    • Instruments – Transformer Oil Testers
      • TOR-1 Oil Moisture Meter
      • TOR-2 Hydrogen and Moisture Analyzer for Transformer Oil Monitoring
      • TOR-3 (TOR-3 SL) Oil Tan Delta Tester
      • TOR-6 Transformer Oil Moisture and Particles Tester
      • TOR-7 Universal Transformer Oil Tester (moisture, gases, solid particles)
      • TOR-8 tester for residual gas content of insulating oil
      • TOR-60 (TOR-60 SL) Breakdown Voltage Tester
      • TOR-80 (TOR-80 LSL) Breakdown Voltage Tester
      • TOR-80A (TOR-80 ASL) Transformer Oils Breakdown Voltage Tester with Battery
      • TOR-100 (TOR-100 SL) Breakdown Voltage Tester
    • Wind Turbine Service
      • CMM-G wind turbine gearbox oil changer (with dimensions adapted to the customer’s trailer ones)
      • CMM-G Wind Turbine Gearbox Oil Changer
      • CMM-GL Wind Turbine Gearbox Oil Changer
      • CMM-0.6L Oil Degassing & Filtration Cart
      • CMM-4,0T Turbine oil filtration
    • Medical Equipment Maintenance
      • CMM-0.6 X-ray Transformer Oil Purifier
      • AVSk-150 Hospital Wastewater Treatment Complex
    • Blending systems
      • USBL-1 Laboratory Blending System
      • USB-1 Fuel oil blending system
      • USB-5 high-speed mixing unit for production of sanitizers (0.15 – 0.3 m3/h)
      • USB-5 high-speed mixing unit for production of sanitizers (1.1 m3/cycle)
      • USB-6 Impeller Stirrer
      • Colloid Mill
      • Vortex Layer Devices
    • Colloid Mill
      • Colloid mills for food industry
        • CLM-100.3 Colloid mill
      • Colloid mills for bitumen emulsion production
        • CLM-0.25.1 Laboratory colloid mill
        • CLM-2/4 Colloid mill
        • CLM-16/25 Colloid mill
      • Colloid mills for bitumen modification
        • CLM-8/16 Colloid mill
        • CLM-10/20 Colloid mill
        • CLM-40.2 Colloid Mill
      • Colloid mills for different applications
        • CLM-100.2 Colloid Mill
        • CLM-200.2 Colloid Mill
    • Vortex Layer Devices
      • AVS-100 Mixing Machine. Vortex Layer Device
      • AVS-150 Chemical Mixing Machine
      • AVSp-100 Vortex Layer Device (Semi-Automated)
      • AVSp-150 vortex layer device (semi-automated)
      • AVSk-150 Wastewater Treatment Complex
    • Bitumen emulsion plant, Bitumen Emulsion Production
      • CLM-0.25.1 Laboratory colloid mill
      • USB-2 Bitumen emulsion unit 2 m3/hour production capacity
      • USB-2 Bitumen emulsion plant 8 m3/hour production capacity
      • FB Bitumen filter
      • USB-6 Impeller Stirrer
    • Bitumen Modification Plant. Modified Bitumen Production
      • USB-3 Bitumen modification laboratory system
      • USB-3 Continuous Bitumen Modification Unit (12 m3/hour)
      • USB-3 Bitumen modification unit 16 m3/hour production capacity
      • USB-4 Modified bitumen collection tank (USB-3)
      • USB-6 Impeller Stirrer
    • Laboratory system for Bitumen Emulsion Samples
      • CLM-0.25.1 Laboratory colloid mill
      • CLM-100.1 Bitumen Emulsion Laboratory System
      • USB-3 Bitumen modification laboratory system
    • Biodiesel Equipment
      • USB-1L Biodiesel laboratory equipment
      • USB-1 Biodiesel equipment
        • Filters
          • The filter GC Fine with a filtration factor β = 4000
        • Vacuum Pumps
          • GC Roots Vacuum Pumps
          • مضخات التفريغ GC Vane (مضخات دعم)
    • Custom Equipment
      • CMM-4R TRANSFORMER OIL REGENERATION MACHINE
      • CMM-1 MOBILE OIL PLANT
      • CMM-2.2 MOBILE OIL PLANT
      • CMM-4 MOBILE UNIT FOR POWERED TRANSFORMER OIL PROCESSING
      • CMM-12A DEGASSING UNIT
      • CMM-1CO CABLE OIL DEGASSING UNIT
      • CMM-5M INDUSTRIAL OIL PURIFICATION MACHINE
      • CMM-8RP Sorbent Reactivation Unit
      • BDK-3 CATALYTIC CONVERTER
      • CMM-600CF TRANSFORMER OIL FILTRATION AND REFILLING MACHINE
      • SN-1 PUMP ASSEMBLY
      • SBE-30 BITUMEN EMULSION COLLECTION TANK (UVB-1)
      • UVB-1 BITUMEN EMULSION UNIT 1 M3/HOUR PRODUCTION CAPACITY
      • UVB-1 EXTENSION 1 M3/HOUR PRODUCTION CAPACITY
      • INDUSTRIAL MIXER – COLLOID MILLS CLM-4 SMALL
      • BIG COLLOIDAL MILL CLM-18 GRINDING MACHINE
      • INDUSTRIAL MILL – GIANT COLLOIDAL MILL CLM-22
      • CMM-0.6 Clean Marine Oil Degassing Cart
      • Compressed Air Supply Unit UOV
    • Accessories & Components
  • Dealers
  • Tech School
    • Webinar Registration
  • News & Articles
  • History
  • Reviews
  • AskMe
  • Contacts
  • EN
    • FR
    • ES
    • PT
    • TH
    • VN
    • CN
    • HA
    • AZ
    • JP
    • DE
    • RO
    • Hun
    • Arabic
    • Ind
GlobeCore / Biodisel / The Difference Between Dry Type and Oil Type Transformers

The Difference Between Dry Type and Oil Type Transformers

Dry transformers are gaining popularity; the main reasons for this preference of transformer owners are better safety and efficiency of such units. In this article we look into whether these reasons are actually true.

The peculiarities of dry and oil transformer systems

The single biggest reason transformer operators prefer dry transformers instead of oil-filled ones is the opportunity to cut down expenses. Dry transformers are commonly considered less demanding in terms of frequent checks and repairs than oil transformers, since they do not use or require an insulation fluid. Such thinking, however, is inaccurate, and lack of care for this type of equipment may lead to dire consequences.

It has also been stated that dry transformers are safer and more stable than oil type transformers, as well as more efficient. In truth, the differences between these different types are more complex: several important factors must be taken into consideration.

The main difference of these two transformer types is the insulation system: both are designed with dry insulation of the windings, but the design principle is different.

Oil transformer insulation

The insulation of oil type transformer consists of liquid and solid insulation, external and internal.

External insulation is located outside of the transformer tank, and is created by the air gaps between the bushings, the bushings and the tank etc.

Internal insulation consists of main (from the winding to the grounded parts of the core, the tank and between the windings) and longitudinal (between different points of the winding, such as turns, coils and layers) insulation.

There are three types of internal insulation:

  • Purely solid insulation 
  • Purely oil insulation
  • Combined insulation

The purpose of oil-filled transformer insulation is the protection of the windings, as well as the bushings, taps and auxiliary components (e.g. switches).

Modern transformers are mostly equipped with oil insulation barriers in combination with solid insulation in certain parts, i.e. combined insulation. Such a system ensures the most efficient and comprehensive insulation.

The benefits and limitations of oil type transformers

The layout and dimensions of oil transformers are designed so that the transformer can deal with thunderstorms and other surge loads.

Interleaved windings are used to minimize the voltage over longitudinal insulation, where turns are connected in a certain order. This may cause difficulties with voltage control, since the windings are under different potentials. In this case, surge voltages can be reduced by increasing the operating voltage; with the rapid development of high voltage technologies and the growth of transformer power, the requirements to stability and strength of the windings and insulation also become higher.

Beside the need for constant monitoring of voltage, achieving long term strength is also important. The windings and the core heat up during operation, so the insulation must also help dissipate heat for efficient and continuous cooling.

Oil insulation has a high dielectric strength and ensures intensive and efficient cooling due to oil circulation.

Dry type transformer insulation

Dry insulation in transformers is a modern technology where air cooling is utilized. This type of units is used where safety is especially important: in metallurgy, petrochemical, paper production, power supply to public buildings etc.

Dry type transformer power ranges from 20 kW to 2500 and even more, they can be equipped either with natural or forced cooling.

High and low voltage windings (HV and LV) in dry transformers are encased in a protective enclosure. Such transformers are installed in dry closed places with humidity below 80%, since contact with air brings moisture into the insulation, while excessive humidity causes premature equipment wear and irreversible consequences. The ability of the windings to absorb moisture is reduced with special lacquer.

There are three kinds of dry type transformers:

  • With open windings
  • With solid cast windings
  • With solid windings
  • Open windings:

Such windings are impregnated with resin by vacuum. The thickness of the insulation is about 0.2 mm. High strength porcelain insulators and insulation profiles (fiberglass and other materials) are used.

  • Solid windings:

These are made by epoxy resin coating in vacuum. Such insulation is suitable for transformers installed in areas with special environmental and fire safety concerns.

  • Solid cast wingins:

Insulation of HV and LV windings is performed by aluminum foil and dielectric film. The windings are reinforced with fiberglass, dried and coated with epoxy resin.

The benefits and limitations of dry type transformers

All dry transformers have both advantages and limitations. In comparison to oil insulation, air insulation is weaker. The quality requirements to dry transformer winding protection are significantly more strict.

The open winding design has special channels for dissipation of heat by convection, sufficient for system cooling. However, the environment poses many risks and complications in transformer maintenance and servicing.

Solid and cast winding transformers are electrically and physically strong and environmentally safe, since they emit no harmful or hazardous substances. The drawback is that with the large mass of insulation material, there may be irregularities (physical or electrical) which cause partial discharges. Besides, cooling of HV windings may be difficult; sharp temperature difference and overheating are a risk.

Maintenance of oil type transformers

Oil requires regular monitoring and replacement. Modern technologies also allow to purify used oil and reuse it. The process of oil change or purification must comply with transformer manuals and instructions.

Beside oil purification and regeneration, the insulation system may require drying and degassing. Moisture and gas, as well as other impurities, are detrimental to the entire transformer and must be removed as soon as their presence is detected.

Despite certain advantages of dry type transformers, which better suited for some applications than oil type transformer, the latter remain more versatile and widely used in electric power industry. It is safe to say that contrary to the common misconception oil type transformers are actually more economical, since the total operating costs are lower than those for dry type transformers.

GlobeCore has developed and manufactures equipment for oil type transformer  maintenance and transformer oil processing.

Some of GlobeCore’s products have many functions, while others focus on specific tasks, such as filtration, drying, degassing or evacuation.

All GlobeCore units are simple to operate; they are often custom designed for the specific customer requirements: a wide range of customizations is available, from capacity to climatic adaptation.

    Leave Your Request


    • Home
    • Products
    • Dealers
    • Tech School
    • Contacts

    ® Copyright by - 2025 © GlobeCore

    GlobeCore, Sadovskogo 14, Poltava, Ukraine, 36034

    This website uses cookies to improve your experience. By continuing to browse, you agree to our use of cookies. Read more in our Privacy Policy.