The purpose of Globecore’s ZP-260 x-ray machines oil drying machine is to eliminate gasses and moisture from insulating oils used in x-ray equipment. Because moisture weakens the insulating qualities of oil and might cause failures, oil quality and purity are essential to the steady operation of X-ray machines. The ZP-260 thoroughly cleans the oil by using vacuum drying technology, which gets rid of even the smallest moisture particles. This keeps medical equipment from overheating, prolongs its oil life, and guarantees smooth functioning. The apparatus restores the original properties of various insulating oil kinds. The ZP-260 is a practical solution for hospitals, diagnostic centers, and service organizations due to its small size and simplicity of use. Both stationary and mobile modes of operation are available for the device.
X-ray machines oil drying machine ZP-260 Specifications
Parameter | Value | |
ZP-130 | ZP-260 | |
Throughput, m3/hour (gpm) | 2 (8.8) | 4 (17.6) |
Number of vessels | 1 | 2 |
Total geometric vessel volume, liters (gallons) | 130 (34.34) | 260 (68.68) |
Oil ISO 4406 purity class | -/14/12 | -/14/12 |
Vessel use mode | Consecutive only | Parallel or consecutive |
Filtration, μm | 5 (1 optionally) | 5 (1 optionally) |
Max oil inlet temperature, °С (°F) | 40 (104) | 40 (104) |
Dimensions, mm (in) | ||
– length | 900 (35) | 1100 (43) |
– width | 760 (29) | 1000 (39) |
– height | 2100 (82) | 2190 (79) |
Weight, kg (lbs) | 170 (374) | 570 (1260) |