GlobeCore

  • Home
  • Products
    • Oil Regeneration
      • CMM-6RL Oil Regeneration Unit
      • CMM-10RL Transformer Oil Regeneration Plant
      • CMM-12R Oil Regeneration Systems
      • CMM-12R Oil Regeneration System (With Activated Bauxite)
      • CMM-8RSL/4000 Transformer Oil Regeneration Plant (With Fuller’s Earth)
      • USB-6 Oxidation Inhibitor injection unit
      • СММ-0,001U Laboratory Oil Filtration Unit
    • Oil Purification & Degassing Machines
      • CMM-0.6L Oil Degassing & Filtration Cart
      • СММur-1L mobile oil plant
      • CMM-1.0LT Transformer Oil Purification Unit
      • CMM-1H Oil Processing Unit
      • CMM-2.2LT Industrial Oil Purification Unit
      • CMM-4,0T Turbine oil filtration
      • CMM-4,0LT Transformer Oil Purification Unit
      • CMM-4/7 portable oil degassing unit
      • CMM-6LT Industrial Oil Purification Unit
      • CMM-6/7 Degassing Unit
      • CMM-8LT Oil Processing Unit
      • CMM-10 — Transformer Oil Purification Machine
      • CMM-15 Oil Degassing Plant
    • Oil Filtration Machines
      • CMM-1,0CF Unit for Removal of Water from Oil
      • CMM-2,0CF Unit for Removal of Water from Oil
      • CMM-1,2Fr Industrial oils filtration unit with self-cleaning filters
      • CMM-4,0F Oil filtration unit
    • Oil Drying Unit
      • ZP-130 Sorbent Cartridges
      • ZP-260 Sorbent Cartridges
    • Oil Heating
      • PPM Inline Oil Heater. Stream oil heating
    • Fuel Polishing
      • TOR-1 diesel fuel moisture content tester
      • CMM-6RL dark diesel fuel polishing machine
      • CMM-6RL dark heating fuel polishing machine
      • CMM-6RL low-viscosity marine fuel polishing machine
    • Online Transformer Dry-Out Systems
      • CMM-260C Online Transformer Dry-Out System
      • TOR-4 Online Transformer Dry-Out System
    • Online Transformer Monitoring Systems
      • TOR-5 Online Transformer Monitoring System
    • Transformer Maintenance
      • Mojave Heat (Sukhovey): Hot Air Dryer Unit
      • UVV Vacuum Cold Trap
      • US-6S Transformer vacuum furnace
      • LFD Low Frequency Heating Device
      • BV-3000 Transformer Evacuation System
      • BV-5000 Transformer Evacuation System
      • UVD Vacuum Oil Filling Unit
      • UVD-1000 Oil Filling and Transportation System
      • TSS Transformer Safety System
      • CMM-6RL Oil Regeneration Unit
      • CMM-10RL Transformer Oil Regeneration Plant
      • CMM-12R Oil Regeneration Systems
    • Vacuum Transformer Drying Ovens
      • US-6S Transformer vacuum furnace
    • Sorbent Processing
      • BRZ Zeolite Regeneration Block
      • BRPS Zeolite Regeneration Block
      • SSC-15 Zeolite Drying Cabinet
      • ZP-130 Sorbent Cartridges
      • ZP-260 Sorbent Cartridges
    • Instruments – Transformer Oil Testers
      • TOR-1 Oil Moisture Meter
      • TOR-2 Hydrogen and Moisture Analyzer for Transformer Oil Monitoring
      • TOR-3 (TOR-3 SL) Oil Tan Delta Tester
      • TOR-6 Transformer Oil Moisture and Particles Tester
      • TOR-7 Universal Transformer Oil Tester (moisture, gases, solid particles)
      • TOR-8 tester for residual gas content of insulating oil
      • TOR-60 (TOR-60 SL) Breakdown Voltage Tester
      • TOR-80 (TOR-80 LSL) Breakdown Voltage Tester
      • TOR-80A (TOR-80 ASL) Transformer Oils Breakdown Voltage Tester with Battery
      • TOR-100 (TOR-100 SL) Breakdown Voltage Tester
    • Wind Turbine Service
      • CMM-G wind turbine gearbox oil changer (with dimensions adapted to the customer’s trailer ones)
      • CMM-G Wind Turbine Gearbox Oil Changer
      • CMM-GL Wind Turbine Gearbox Oil Changer
      • CMM-0.6L Oil Degassing & Filtration Cart
      • CMM-4,0T Turbine oil filtration
    • Medical Equipment Maintenance
      • CMM-0.6 X-ray Transformer Oil Purifier
      • SSC-15 Zeolite Regeneration System for Oxygen Concentrators
      • AVSk-150 Hospital Wastewater Treatment Complex
    • Blending systems
      • USBL-1 Laboratory Blending System
      • USB-1 Fuel oil blending system
      • USB-5 high-speed mixing unit for production of sanitizers (0.15 – 0.3 m3/h)
      • USB-5 high-speed mixing unit for production of sanitizers (1.1 m3/cycle)
      • USB-6 Impeller Stirrer
      • Colloid Mill
      • Vortex Layer Devices
    • Colloid Mill
      • Colloid mills for food industry
        • CLM-100.3 Colloid mill
      • Colloid mills for bitumen emulsion production
        • CLM-0.25.1 Laboratory colloid mill
        • CLM-2/4 Colloid mill
        • CLM-16/25 Colloid mill
      • Colloid mills for bitumen modification
        • CLM-8/16 Colloid mill
        • CLM-10/20 Colloid mill
        • CLM-40.2 Colloid Mill
      • Colloid mills for different applications
        • CLM-100.2 Colloid Mill
        • CLM-200.2 Colloid Mill
    • Vortex Layer Devices
      • AVS-100 Mixing Machine. Vortex Layer Device
      • AVS-150 Chemical Mixing Machine
      • AVSp-100 Vortex Layer Device (Semi-Automated)
      • AVSp-150 vortex layer device (semi-automated)
      • AVSk-150 Wastewater Treatment Complex
    • Bitumen emulsion plant, Bitumen Emulsion Production
      • CLM-0.25.1 Laboratory colloid mill
      • USB-2 Bitumen emulsion unit 2 m3/hour production capacity
      • USB-2 Bitumen emulsion plant 8 m3/hour production capacity
      • FB Bitumen filter
      • USB-6 Impeller Stirrer
    • Bitumen Modification Plant. Modified Bitumen Production
      • USB-3 Bitumen modification laboratory system
      • USB-3 Continuous Bitumen Modification Unit (12 m3/hour)
      • USB-3 Bitumen modification unit 16 m3/hour production capacity
      • USB-4 Modified bitumen collection tank (USB-3)
      • USB-6 Impeller Stirrer
    • Laboratory system for Bitumen Emulsion Samples
      • CLM-0.25.1 Laboratory colloid mill
      • CLM-100.1 Bitumen Emulsion Laboratory System
      • USB-3 Bitumen modification laboratory system
    • Biodiesel Equipment
      • USB-1L Biodiesel laboratory equipment
      • USB-1 Biodiesel equipment
        • Filters
          • The filter GC Fine with a filtration factor β = 4000
        • Vacuum Pumps
          • GC Roots Vacuum Pumps
          • مضخات التفريغ GC Vane (مضخات دعم)
    • Custom Equipment
      • CMM-4R TRANSFORMER OIL REGENERATION MACHINE
      • CMM-1 MOBILE OIL PLANT
      • CMM-2.2 MOBILE OIL PLANT
      • CMM-4 MOBILE UNIT FOR POWERED TRANSFORMER OIL PROCESSING
      • CMM-12A DEGASSING UNIT
      • CMM-1CO CABLE OIL DEGASSING UNIT
      • CMM-5M INDUSTRIAL OIL PURIFICATION MACHINE
      • MCU ZEOLITE OIL DRYING UNIT
      • CMM-8RP Sorbent Reactivation Unit
      • BDK-3 CATALYTIC CONVERTER
      • CMM-600CF TRANSFORMER OIL FILTRATION AND REFILLING MACHINE
      • SN-1 PUMP ASSEMBLY
      • SBE-30 BITUMEN EMULSION COLLECTION TANK (UVB-1)
      • UVB-1 BITUMEN EMULSION UNIT 1 M3/HOUR PRODUCTION CAPACITY
      • UVB-1 EXTENSION 1 M3/HOUR PRODUCTION CAPACITY
      • INDUSTRIAL MIXER – COLLOID MILLS CLM-4 SMALL
      • BIG COLLOIDAL MILL CLM-18 GRINDING MACHINE
      • INDUSTRIAL MILL – GIANT COLLOIDAL MILL CLM-22
      • CMM-0.6 Clean Marine Oil Degassing Cart
      • Compressed Air Supply Unit UOV
    • Accessories & Components
  • Dealers
  • Tech School
    • Webinar Registration
  • News & Articles
  • History
  • Reviews
  • AskMe
  • Contacts
  • EN
    • FR
    • ES
    • PT
    • TH
    • VN
    • CN
    • HA
    • AZ
    • JP
    • DE
    • RO
    • Hun
    • Arabic
    • Ind
GlobeCore / Oil Regeneration / Transformer Oil Degradation Analysis

Transformer Oil Degradation Analysis

Transformer oil Degradation

Transformer oil degradation is a process caused by a number of factors. It can be the result of thermal, mechanical stresses and a few other things. Aging of transformer oil leads to many possible failures. That is why proper transformer maintenance is important.

Transformer oil maintenance

Maintenance of transformer oil should include several important phases, which should not be omitted. First of all, every transformer and its contents needs regular control and analysis. Impurities or other suspicious changes must be found as soon as possible. Purity of transformer oil is crucial. When problems in the system are neglected, transformer oil degradation will lead to serious consequences.

The next phase of transformer oil maintenance should be changing or purifying it. This can be done in several different ways. The simple basic oil change can be a long and a rather expensive procedure. The biggest  problem is the raw material cost. Due to the fact that oil change must be performed regularly (with varying frequency), transformer maintenance can be worth a fortune. However, there are technologies that allow to clear up used transformer oil. This way, maintenance costs can be reduced significantly. Some companies, such as GlobeCore, design special equipment for automatic oil purification, pumping, dehydration etc.

The frequency of transformer oil analysis depends on transformer specifics. Some transformers require annual service, while others must be serviced quarterly or even monthly.

Why transformer oil analysis is important

Transformer oil functions as an electrical insulator, coolant etc. This makes its condition very important for correct and reliable operation of transformers.

With time, transformer oil deteriorates due to oxidation and moisture ingress. Transformer oil should be tested properly and frequently.  Changes in the oil have a significant impact on economic performance, transformer reliability and other factors. So utility companies have a vested interest in periodic oil testing. Through such testing, transformer life can be substantially increased, delaying the need to invest into replacement of the equipment. To avoid trouble, any suspicious changes in the oil must be addressed immediately.

Transformer Oil IFT test

The purpose of transformer oil interfacial tension test is to estimate the level of transformer oil degradation.

Various types of impurities may be found in the oil: oxidation byproducts, acids etc.  The presence of these hydrophilic materials in the insulating fluid can affect the chemical (acidity), electrical (dielectric strength), and physical (interfacial tension) properties of the fluid. This analysis  measures the surface tension of oil against water, which is highly polar. The higher the difference in polarity between the two liquids, the lower the index of the interfacial tension between them. Therefore, the higher the concentration of hydrophilic materials in the insulating fluid, the lower the interfacial tension of the oil is. There are several methods of interfacial tension tests against water:

  • Measuring the size of a water droplet

It is a simple method, in which a droplet of water below the surface of the oil is analyzed.

  • The ring method

The ring method of transformer oil degradation analysis (IFT) against water is as follows: a special device, called tensiometer is used. It measures interfacial tension based on Du Nouy principle. A sample of oil is carefully floated on top of water. Then the force necessary to pull a platinum ring upward from below the water through the oil is measured with the help of a calibrated torsion wire. The force is measured at the point at which the ring breaks free of the water as it is being pulled upward through the oil layer. The platinum ring is made to precise dimensions. Since this test is very sensitive to trace contaminants, one must be very thorough in handling the sampling device, the sample, and the instrument. There are correction factors that have to be taken into consideration associated with the dimensions of the ring and the densities of the water and the oil sample. The results are given in units of dynes/cm or the numerically equivalent units of milliNewtons/meter (mN/m).

Transformer oil Features

  • Transformer oil density

The density of transformer oil is one of its most important physical characteristics. Oil density has a large impact on the operation of your electrical power transformers. It is therefore important to pay close attention to oil density when filling or refilling your electrical transformers with dielectric insulating oil.

The specific density of transformer oil varies based on the manufacturer and the region or location where the oil is primarily used.  Despite the variables that determine the density of the oil, it must not exceed 900 kg/m3 at +20°C/+68°F.

Transformer oil density is defined as the ratio of the mass of the substance to the volume of the substance.  Simply stated, it is the ratio of the weight of the oil to the volume of the oil. Transformer oil temperature also has an effect on the density of transformer oil.  As the temperature increases, the density of the oil decreases.

  • Transformer Oil Color

The color and appearance of transformer oil are useful for comparative evaluation: rapid darkening or dark color of the oil is a sign of oil aging. Oil color is assigned a number ranging from 1 to 8: the darker the oil, the higher the color index.

Undesirable contaminants can be detected by analyzing the appearance of the oil. Turbidity or sediment indicate free water, insoluble sludge or dust particles. If these are present, breakdown voltage and/or dissipation factor, as well as other parameters, are likely out of specs and corrective measures are necessary.

Transformer Oil Degradation Test by GlobeCore

Transformer oil degradation analysis can be made much simpler: GlobeCore offers a special laboratory scale unit to assist with oil analysis, the СММ-0,001U. This unit will help in the analysis of not only transformer, but also turbine, diesel and other oils. You can order this GlobeCore device or, alternately, request oil sample testing at our facilities.

    Leave Your Request


    • Home
    • Products
    • Dealers
    • Tech School
    • Contacts

    ® Copyright by - 2025 © GlobeCore

    GlobeCore, Sadovskogo 14, Poltava, Ukraine, 36034

    This website uses cookies to improve your experience. By continuing to browse, you agree to our use of cookies. Read more in our Privacy Policy.