GlobeCore

  • Home
  • Products
    • Oil Regeneration
      • CMM-6RL Oil Regeneration Unit
      • CMM-10RL Transformer Oil Regeneration Plant
      • CMM-12R Oil Regeneration Systems
      • CMM-12R Oil Regeneration System (With Activated Bauxite)
      • CMM-8RSL/4000 Transformer Oil Regeneration Plant (With Fuller’s Earth)
      • USB-6 Oxidation Inhibitor injection unit
      • СММ-0,001U Laboratory Oil Filtration Unit
    • Oil Purification & Degassing Machines
      • CMM-0.6L Oil Degassing & Filtration Cart
      • СММur-1L mobile oil plant
      • CMM-1.0LT Transformer Oil Purification Unit
      • CMM-1H Oil Processing Unit
      • CMM-2.2LT Industrial Oil Purification Unit
      • CMM-4,0T Turbine oil filtration
      • CMM-4,0LT Transformer Oil Purification Unit
      • CMM-4/7 portable oil degassing unit
      • CMM-6LT Industrial Oil Purification Unit
      • CMM-6/7 Degassing Unit
      • CMM-8LT Oil Processing Unit
      • CMM-10 — Transformer Oil Purification Machine
      • CMM-15 Oil Degassing Plant
    • Oil Filtration Machines
      • CMM-1,0CF Unit for Removal of Water from Oil
      • CMM-2,0CF Unit for Removal of Water from Oil
      • CMM-1,2Fr Industrial oils filtration unit with self-cleaning filters
      • CMM-4,0F Oil filtration unit
    • Oil Drying Unit
      • ZP-130 Sorbent Cartridges
      • ZP-260 Sorbent Cartridges
    • Oil Heating
      • PPM Inline Oil Heater. Stream oil heating
    • Fuel Polishing
      • TOR-1 diesel fuel moisture content tester
      • CMM-6RL dark diesel fuel polishing machine
      • CMM-6RL dark heating fuel polishing machine
      • CMM-6RL low-viscosity marine fuel polishing machine
    • Online Transformer Dry-Out Systems
      • CMM-260C Online Transformer Dry-Out System
      • TOR-4 Online Transformer Dry-Out System
    • Online Transformer Monitoring Systems
      • TOR-5 Online Transformer Monitoring System
    • Transformer Maintenance
      • Mojave Heat (Sukhovey): Hot Air Dryer Unit
      • UVV Vacuum Cold Trap
      • US-6S Transformer vacuum furnace
      • LFD Low Frequency Heating Device
      • BV-3000 Transformer Evacuation System
      • BV-5000 Transformer Evacuation System
      • UVD Vacuum Oil Filling Unit
      • UVD-1000 Oil Filling and Transportation System
      • TSS Transformer Safety System
      • CMM-6RL Oil Regeneration Unit
      • CMM-10RL Transformer Oil Regeneration Plant
      • CMM-12R Oil Regeneration Systems
    • Vacuum Transformer Drying Ovens
      • US-6S Transformer vacuum furnace
    • Sorbent Processing
      • BRZ Zeolite Regeneration Block
      • BRPS Zeolite Regeneration Block
      • SSC-15 Zeolite Drying Cabinet
      • ZP-130 Sorbent Cartridges
      • ZP-260 Sorbent Cartridges
    • Instruments – Transformer Oil Testers
      • TOR-1 Oil Moisture Meter
      • TOR-2 Hydrogen and Moisture Analyzer for Transformer Oil Monitoring
      • TOR-3 (TOR-3 SL) Oil Tan Delta Tester
      • TOR-6 Transformer Oil Moisture and Particles Tester
      • TOR-7 Universal Transformer Oil Tester (moisture, gases, solid particles)
      • TOR-8 tester for residual gas content of insulating oil
      • TOR-60 (TOR-60 SL) Breakdown Voltage Tester
      • TOR-80 (TOR-80 LSL) Breakdown Voltage Tester
      • TOR-80A (TOR-80 ASL) Transformer Oils Breakdown Voltage Tester with Battery
      • TOR-100 (TOR-100 SL) Breakdown Voltage Tester
    • Wind Turbine Service
      • CMM-G wind turbine gearbox oil changer (with dimensions adapted to the customer’s trailer ones)
      • CMM-G Wind Turbine Gearbox Oil Changer
      • CMM-GL Wind Turbine Gearbox Oil Changer
      • CMM-0.6L Oil Degassing & Filtration Cart
      • CMM-4,0T Turbine oil filtration
    • Medical Equipment Maintenance
      • CMM-0.6 X-ray Transformer Oil Purifier
      • SSC-15 Zeolite Regeneration System for Oxygen Concentrators
      • AVSk-150 Hospital Wastewater Treatment Complex
    • Blending systems
      • USBL-1 Laboratory Blending System
      • USB-1 Fuel oil blending system
      • USB-5 high-speed mixing unit for production of sanitizers (0.15 – 0.3 m3/h)
      • USB-5 high-speed mixing unit for production of sanitizers (1.1 m3/cycle)
      • USB-6 Impeller Stirrer
      • Colloid Mill
      • Vortex Layer Devices
    • Colloid Mill
      • Colloid mills for food industry
        • CLM-100.3 Colloid mill
      • Colloid mills for bitumen emulsion production
        • CLM-0.25.1 Laboratory colloid mill
        • CLM-2/4 Colloid mill
        • CLM-16/25 Colloid mill
      • Colloid mills for bitumen modification
        • CLM-8/16 Colloid mill
        • CLM-10/20 Colloid mill
        • CLM-40.2 Colloid Mill
      • Colloid mills for different applications
        • CLM-100.2 Colloid Mill
        • CLM-200.2 Colloid Mill
    • Vortex Layer Devices
      • AVS-100 Mixing Machine. Vortex Layer Device
      • AVS-150 Chemical Mixing Machine
      • AVSp-100 Vortex Layer Device (Semi-Automated)
      • AVSp-150 vortex layer device (semi-automated)
      • AVSk-150 Wastewater Treatment Complex
    • Bitumen emulsion plant, Bitumen Emulsion Production
      • CLM-0.25.1 Laboratory colloid mill
      • USB-2 Bitumen emulsion unit 2 m3/hour production capacity
      • USB-2 Bitumen emulsion plant 8 m3/hour production capacity
      • FB Bitumen filter
      • USB-6 Impeller Stirrer
    • Bitumen Modification Plant. Modified Bitumen Production
      • USB-3 Bitumen modification laboratory system
      • USB-3 Continuous Bitumen Modification Unit (12 m3/hour)
      • USB-3 Bitumen modification unit 16 m3/hour production capacity
      • USB-4 Modified bitumen collection tank (USB-3)
      • USB-6 Impeller Stirrer
    • Laboratory system for Bitumen Emulsion Samples
      • CLM-0.25.1 Laboratory colloid mill
      • CLM-100.1 Bitumen Emulsion Laboratory System
      • USB-3 Bitumen modification laboratory system
    • Biodiesel Equipment
      • USB-1L Biodiesel laboratory equipment
      • USB-1 Biodiesel equipment
        • Filters
          • The filter GC Fine with a filtration factor β = 4000
        • Vacuum Pumps
          • GC Roots Vacuum Pumps
          • مضخات التفريغ GC Vane (مضخات دعم)
    • Custom Equipment
      • CMM-4R TRANSFORMER OIL REGENERATION MACHINE
      • CMM-1 MOBILE OIL PLANT
      • CMM-2.2 MOBILE OIL PLANT
      • CMM-4 MOBILE UNIT FOR POWERED TRANSFORMER OIL PROCESSING
      • CMM-12A DEGASSING UNIT
      • CMM-1CO CABLE OIL DEGASSING UNIT
      • CMM-5M INDUSTRIAL OIL PURIFICATION MACHINE
      • MCU ZEOLITE OIL DRYING UNIT
      • CMM-8RP Sorbent Reactivation Unit
      • BDK-3 CATALYTIC CONVERTER
      • CMM-600CF TRANSFORMER OIL FILTRATION AND REFILLING MACHINE
      • SN-1 PUMP ASSEMBLY
      • SBE-30 BITUMEN EMULSION COLLECTION TANK (UVB-1)
      • UVB-1 BITUMEN EMULSION UNIT 1 M3/HOUR PRODUCTION CAPACITY
      • UVB-1 EXTENSION 1 M3/HOUR PRODUCTION CAPACITY
      • INDUSTRIAL MIXER – COLLOID MILLS CLM-4 SMALL
      • BIG COLLOIDAL MILL CLM-18 GRINDING MACHINE
      • INDUSTRIAL MILL – GIANT COLLOIDAL MILL CLM-22
      • CMM-0.6 Clean Marine Oil Degassing Cart
      • Compressed Air Supply Unit UOV
    • Accessories & Components
  • Dealers
  • Tech School
    • Webinar Registration
  • News & Articles
  • History
  • Reviews
  • AskMe
  • Contacts
  • EN
    • FR
    • ES
    • PT
    • TH
    • VN
    • CN
    • HA
    • AZ
    • JP
    • DE
    • RO
    • Hun
    • Arabic
    • Ind
GlobeCore / Oil Regeneration / Transformer Oil Dewatering

Transformer Oil Dewatering

Transformer Oil Deterioration

Any oil used in electrical equipment must comply with certain requirements. I.e. its quality and parameters must not be below the values stated in regulatory documents and equipment manuals. Any deviation may lead to transformer malfunction and outrage. Some of the most important indications of oil quality are its dielectric strength, moisture and gas content. For instance, oil for 750 kV transformers must not contain more than 0.001% water and 0.15% gas (by volume). These requirements make degassing and dewatering of transformer oil an essential component of transformer servicing.

Where does the water come from?

Water in the oil may come from two sources: from the atmosphere or as a result of the aging processes in the solid insulation of a transformer.

Water can be present in the oil in varying forms. It may be absorbed, solved, emulsified or free. In the first case, water molecules are tightly bound to oil molecules. In this form the water has little impact on the dielectric strength of the oil. However, with temperature changes, this water may become solved or emulsified. In the second case, the molecules of water are between the oil molecules and not in direct contact with each other. Such was also has little effect on the dielectric strength. The most dangerous forms of water content are emulsified and free water. Emulsified water forms when the molecules coagulate into small droplets. In turn, free water forms from emulsified water or as a result of large water droplets entering the oil directly.

What makes water dangerous?

Spherical water droplets in the oil stretch in the electromagnetic field. These droplets become elliptical and are attracted to one another due to different charges on the ends. This process results in formation of chains with increased conductivity, which cause electrical breakthroughs. A significant decrease of dielectric strength can be caused by even a small amount of water. Water amounts above 50 ppm can cause breakthroughs and transformer failure.

Water also has other adverse effects, such as:

  • accelerated aging of paper insulation;
  • increased carbon formation during arcing;
  • increased corrosion of metal parts of the transformer;
  • accelerated oxidation of oil;
  • deterioration of physical oil properties under increased temperatures.

The above factors are sufficient to understand how important transformer oil dewatering is.

Protecting transformer oil from water

One of the preventive measures to protect transformer oil from water is to create a layer of gas between the oil and the air (e.g. nitrogen). This layer becomes the barrier between the oil and the water in the air.

Another measure are cartridges filled with silica gel. This adsorbent captures water and prevents it from contacting with the transformer oil.

Still, even with the best preventive measures in place, it is impossible to completely prevent presence of water in the oil. This is where transformer oil dewatering comes in.

What is used for transformer oil dewatering

Centrifuges and filter-presses were used to solve this problem in the past. However, these were cumbersome and complicated in operation. New equipment has been developed, based on two different approaches: processing of oil with adsorbents, as well as heat and vacuum treatment. These methods are now the most common.

Transformer oil dewatering by heating

The heating method of transformer oil dewatering involves evaporation of water at atmospheric pressure or in vacuum. If the oil contaminated with water is heated above 100°С, it will start to foam. Besides, oxidation processes will intensify, especially if the oil contains no antioxidant additives. Therefore the oil is only heated to 80-90°С under atmospheric pressure, which only allows to evaporate a part of the water. Complete removal of water is possible under vacuum. This method is highly efficient even in cases where the oil forms a stable emulsion with the water, which is difficult to separate otherwise. Oxidation is also not a factor in this process, as there is no air in the vacuum chamber.

Transformer oil dewatering with zeolite

Another method transformer oil dewatering is adsorbent treatment. We have mentioned the use of silica gel for oil protection above. When the oil already contains a lot of water, zeolite (a molecular sieve) is used. These adsorbents capture a lot of water, so they can be used to dewater oil with a large amount of water. Adsorption is recommended for oil with dielectric strength of 10 kV and higher. It should be noted that zeolite does not absorb hydrocarbon substances and aging products. This means that oil regeneration requires other adsorbent media; zeolite can be used in the pretreatment stage of regeneration.

When zeolite is saturated, it is reactivated to restore its properties. Besides, each reactivation makes that a part of the adsorbent is lost. In this regard, transformer oil dewatering with heat and vacuum is better, since it does not generate waste which requires disposal. On the other hand, the zeolite process does not require heating, as the process occurs efficiently at 15-25°С. One pass through the zeolite unit can increase the dielectric strength of the oil to 60 kV (from10-20 kV), and water content decreases by an order of magnitude.

In general, the zeolite transformer oil dewatering unit includes adsorbent columns (usually operated in parallel), an oil pump, an oil heater and a filter. Particulate matter is removed from the oil by the filter, then its temperature is increased by the heater and it is supplied to the adsorbent columns by the pump.

GlobeCore transformer oil dewatering processes

GlobeCore always strives to offer a wide range of options to clients. We have equipment both for zeolite dewatering of oil and for the heating and vacuum process. In the former case, you can use the MCU units, in the latter case we offer the CMM type units.

The MCU units are based on the classical adsorption process technology. For ease of operation and reduction of down time, zeolite can be reactivated by connecting the unit to BRZ-100 zeolite regeneration unit.

The CMM units are designed for different capacities (starting with 600 liters/hour). Larger and more powerful units of this type can also pull vacuum on transformers and fill transformer with oil, beside the primary function of degassing, dewatering and filtration of transformer oil.

GlobeCore equipment is designed and manufactured with consideration of all customer requirements. We select component parts, construction material, unit mobility (stationary, on wheels or on trailerized), extra options (particle counters, remote control etc) individually. Our specialists are always ready to offer free qualified advice on purification and regeneration of transformer oil in general and transformer oil dewatering specifically.

    Leave Your Request


    • Home
    • Products
    • Dealers
    • Tech School
    • Contacts

    ® Copyright by - 2025 © GlobeCore

    GlobeCore, Sadovskogo 14, Poltava, Ukraine, 36034

    This website uses cookies to improve your experience. By continuing to browse, you agree to our use of cookies. Read more in our Privacy Policy.