GlobeCore / Application / Lubricating oil moisture and particles content tester TOR-6

Lubricating oil moisture and particles content tester TOR-6

Lubricating oil moisture and particles content tester TOR-6

The TOR-6 lubricating oil moisture and particles content tester, manufactured by GlobeCore, has been developed for the purpose of monitoring the purity and condition of lubricating fluids in various types of equipment. During operation, foreign particles such as metal, abrasive, wear product residues, and water can enter the oil. The timely detection of such contaminants is therefore of paramount importance in order to prevent premature wear of components and malfunctions of equipment. TOR-6 performs two primary measurements: it determines the amount of mechanical impurities in the fluid and records the presence of water or excess moisture. The measurement results allow for a rapid evaluation of the suitability of the oil for further use, or for the determination of the necessity for replacement or filtration. The device is characterised by its portability and ease of use, rendering it suitable for deployment in both laboratory and field settings. The apparatus is equipped with a digital display, an intuitive interface, and a system for the storage of results. A minimal quantity of sample is adequate for the purpose of measurements. The TOR-6 assists companies in the continuous monitoring of lubricants, thereby extending the lifespan of equipment, mitigating the risk of breakdowns, and optimising maintenance costs.

Lubricating oil moisture and particles content tester TOR-6 Specifications

No. Parameter Value
Moisture measurement characteristics
1 Operating range, aw (active water) 0…1
 2 Precision at 20 °C ±10 % or ±10 ppm
3 Temperature measurement Yes
Purity or contamination level characteristics
4 Permissible viscosity range, mm²/sec 1 to 1,000
5 Standards maintained in determining the purity class ISO 99 (ISO 4406:1999)

SAE (SAE AS 4059) or

ISO 87 (ISO 4406:1987)

NAS (NAS 1638)

6 Measuring range Measuring from ISO 9/8/7 (min) to ISO 25/24/23 (max)

Calibrated within the ISO range from 13/11/10 to 23/21/18

7 Precision ISO class ± 1/2 in calibrated range
8 Required power, W 3
9 Single phase 50 Hz AC power supply voltage, V 220
10 Dimensions, mm, not more than

– length

– width

– height

 

235

275

370

11 Weight, kg, not more than 10

    Leave Your Request