GlobeCore FAQ
Is the USB-3 modification unit suitable for sulfur polymer?
- This topic has 1 reply, 2 voices, and was last updated 1 week, 1 day ago by .
Answers
-
January 21, 2026 at 4:31 am by Lucas Martins
Yes – USB-3 is suitable for sulfur polymer / sulfur-modified PMB, provided the unit is ordered/configured with the sulfur dosing (input) assembly and the recipe is run within the correct temperature window for your sulfur/polymer system. GlobeCore’s USB-3 is described as capable of implementing “virtually any bitumen modification process” using a wide range of modifiers and additives, and their configurator explicitly lists a Sulfur input assembly as an available option. Capacity depends on the USB-3 version, but typical industrial configurations are in the 8-12 m³/h range (and higher on other variants), while sulfur addition is treated as an additive stream inside the standard continuous process.