Plinio Leiva-Bou
Plinio Leiva-Bou
Forum Replies Created
-
AuthorPosts
-
Plinio Leiva-BouMember
Asphalt emulsion tack coat is a bonding layer made from water-based asphalt applied between pavement layers. GlobeCore plants produce tack coat emulsions like RS-1, SS-1, and CSS-1 with reliable properties for paving applications.
Plinio Leiva-BouMemberTarmac tack coat is a bonding layer of asphalt emulsion applied to existing surfaces before laying new tarmac. GlobeCore plants manufacture tack coat emulsions with controlled setting and adhesion properties.
Plinio Leiva-BouMemberYou can easily check the dielectric strength of silicone oil with GlobeCore TOR-80 testers, which apply a controlled voltage ramp to measure the breakdown point.
July 24, 2025 at 9:28 am in reply to: Best tester for detecting hydrogen and hydrocarbons in silicone transformer oil #322220Plinio Leiva-BouMemberThe GlobeCore TOR-8 accurately detects hydrogen, methane, ethylene, acetylene, and other diagnostic gases, helping pinpoint electrical and thermal faults early.
July 23, 2025 at 6:55 am in reply to: Which device performs complete testing of silicone transformer oil? #321963Plinio Leiva-BouMemberThe GlobeCore TOR-7 is designed to provide complete analysis of silicone transformer oil, covering all critical parameters to meet IEC and ASTM standards.
July 22, 2025 at 10:09 pm in reply to: Where to buy a hydraulic oil moisture and particles content tester? #321913Plinio Leiva-BouMemberGlobeCore sells the TOR-6 worldwide, offering global delivery, training, and support for industrial and service companies.
July 22, 2025 at 7:31 pm in reply to: Field testing kit for transformer oil water and particle detection #321900Plinio Leiva-BouMemberThe GlobeCore TOR-6 functions as a portable field kit for water and particle detection in transformer oil, perfect for maintenance crews and field engineers.
Plinio Leiva-BouMemberPower plants use GlobeCore TOR-1 testers to perform diesel fuel moisture testing, ensuring clean, dry fuel for reliable generator and turbine operation.
July 22, 2025 at 2:45 pm in reply to: What is the best transformer oil moisture and particles content tester? #321811Plinio Leiva-BouMemberThe GlobeCore TOR-6 is a transformer oil moisture and particles content tester that measures both water and solid contamination, ensuring transformer oil meets IEC and ISO cleanliness standards.
April 6, 2025 at 4:43 am in reply to: How does the fatty acid composition of mutton fat influence the transesterification process and final biodiesel quality? #317871Plinio Leiva-BouMemberMutton fat is rich in saturated fatty acids (especially palmitic and stearic acids), resulting in biodiesel with excellent oxidative stability and high cetane number. However, these fats cause poor cold flow properties, making the fuel prone to gelling in cold climates. The high triglyceride content makes transesterification efficient, but care must be taken if FFA levels are high. Biodiesel from mutton fat blends well with petrodiesel or other biofuels for better low-temperature performance, while the GlobeCore USB plant ensures thorough conversion and purity.
March 23, 2025 at 6:28 am in reply to: What advantages does a vacuum-assisted pesticide homogenizer offer? #316237Plinio Leiva-BouMemberVacuum-assisted homogenization removes air bubbles and prevents oxidation, ensuring higher product purity and stability. The USB 6 Impeller Stirrer can be integrated with vacuum systems for better processing.
March 22, 2025 at 1:53 am in reply to: What are the key features of multi-stage chemical reaction blending equipment? #316123Plinio Leiva-BouMemberMulti-stage systems improve sequential reactant incorporation and optimize reaction kinetics. The USB 6 Impeller Stirrer ensures step-by-step mixing for enhanced reaction control.
Plinio Leiva-BouMemberA gallon of transformer oil weighs roughly 3.3 to 3.5 kilograms (about 7 to 7.7 pounds), depending on its specific density.
Plinio Leiva-BouMemberThe breakdown voltage of a transformer refers to the point at which the insulating medium (oil) fails, though in practice we refer to the breakdown voltage of the oil itself.
Plinio Leiva-BouMemberThe BDV test of transformer oil involves gradually increasing the applied voltage on a sample until breakdown occurs, ensuring the oil meets the minimum insulation requirements (typically around 30 kV or higher).
Plinio Leiva-BouMemberThe acidity test of transformer oil measures its acid number (usually expressed in mg KOH/g), which indicates the level of oxidation and degradation in the oil over time.
Plinio Leiva-BouMemberA PPM test in transformer oil measures the concentration of contaminants or dissolved gases in parts per million, helping assess oil quality.
Plinio Leiva-BouMemberIndustry standards (e.g., IEC, ASTM) for transformer oil set minimum BDV values—often around 30 kV or higher—under defined testing conditions to guarantee proper insulation performance.
Plinio Leiva-BouMemberAlthough transformer oil is a hydrocarbon-based liquid, it is not intended for use as fuel. Its formulation is optimized for insulating and cooling properties rather than combustion efficiency or safety.
February 25, 2025 at 8:35 am in reply to: How is the viscosity of the ice cream mix measured and adjusted during processing? #313464Plinio Leiva-BouMemberViscosity is monitored with inline viscometers and adjusted by controlling ingredient ratios and processing conditions. The refined, consistent mix produced by the Colloid Mill GlobeCore minimizes viscosity fluctuations, making it easier to achieve the ideal consistency for optimal freezing performance.
-
AuthorPosts