GlobeCore.com

  • Home
  • Products
    • Oil Regeneration
      • CMM-6RL Oil Regeneration Unit
      • CMM-10RL Transformer Oil Regeneration Plant
      • CMM-12R Oil Regeneration Systems
      • CMM-12R Oil Regeneration System (With Activated Bauxite)
      • CMM-8RSL/4000 Transformer Oil Regeneration Plant (With Fuller’s Earth)
      • USB-6 Oxidation Inhibitor injection unit
      • СММ-0,001U Laboratory Oil Filtration Unit
    • Oil Purification & Degassing Machines
      • CMM-0.6L Oil Degassing & Filtration Cart
      • СММur-1L mobile oil plant
      • CMM-1.0LT Transformer Oil Purification Unit
      • CMM-1H Oil Processing Unit
      • CMM-2.2LT Industrial Oil Purification Unit
      • CMM-4,0T Turbine oil filtration
      • CMM-4,0LT Transformer Oil Purification Unit
      • CMM-4/7 portable oil degassing unit
      • CMM-6LT Industrial Oil Purification Unit
      • CMM-6/7 Degassing Unit
      • CMM-8LT Oil Processing Unit
      • CMM-10 — Transformer Oil Purification Machine
      • CMM-15 Oil Degassing Plant
    • Oil Filtration Machines
      • CMM-1,0CF Unit for Removal of Water from Oil
      • CMM-2,0CF Unit for Removal of Water from Oil
      • CMM-1,2Fr Industrial oils filtration unit with self-cleaning filters
      • CMM-4,0F Oil filtration unit
    • Oil Drying Unit
      • ZP-130 Sorbent Cartridges
      • ZP-260 Sorbent Cartridges
    • Oil Heating
      • PPM Inline Oil Heater. Stream oil heating
    • Fuel Polishing
      • TOR-1 diesel fuel moisture content tester
      • CMM-6RL dark diesel fuel polishing machine
      • CMM-6RL dark heating fuel polishing machine
      • CMM-6RL low-viscosity marine fuel polishing machine
    • Online Transformer Dry-Out Systems
      • CMM-260C Online Transformer Dry-Out System
      • TOR-4 Online Transformer Dry-Out System
    • Online Transformer Monitoring Systems
      • TOR-5 Online Transformer Monitoring System
    • Transformer Maintenance
      • Mojave Heat (Sukhovey): Hot Air Dryer Unit
      • UVV Vacuum Cold Trap
      • US-6S Transformer Drying Oven
      • LFD Low Frequency Heating Device
      • BV-3000 Transformer Evacuation System
      • BV-5000 Transformer Evacuation System
      • UVD Vacuum Oil Filling Unit
      • UVD-1000 Oil Filling and Transportation System
      • TSS Transformer Safety System
      • CMM-6RL Oil Regeneration Unit
      • CMM-10RL Transformer Oil Regeneration Plant
      • CMM-12R Oil Regeneration Systems
    • Vacuum Transformer Drying Ovens
      • US-6S Transformer Drying Oven
    • Sorbent Processing
      • ZP-130 Sorbent Cartridges
      • ZP-260 Sorbent Cartridges
    • Instruments – Transformer Oil Testers
      • TOR-1 Oil Moisture Meter
      • TOR-2 Hydrogen and Moisture Analyzer for Transformer Oil Monitoring
      • TOR-3 (TOR-3 SL) Oil Tan Delta Tester
      • TOR-6 Transformer Oil Moisture and Particles Tester
      • TOR-7 Universal Transformer Oil Tester (moisture, gases, solid particles)
      • TOR-8 tester for residual gas content of insulating oil
      • TOR-60 (TOR-60 SL) Breakdown Voltage Tester
      • TOR-80 (TOR-80 LSL) Breakdown Voltage Tester
      • TOR-80A (TOR-80 ASL) Transformer Oils Breakdown Voltage Tester with Battery
      • TOR-100 (TOR-100 SL) Breakdown Voltage Tester
    • Wind Turbine Service
      • CMM-G wind turbine gearbox oil changer (with dimensions adapted to the customer’s trailer ones)
      • CMM-G Wind Turbine Gearbox Oil Changer
      • CMM-GL Wind Turbine Gearbox Oil Changer
      • CMM-0.6L Oil Degassing & Filtration Cart
      • CMM-4,0T Turbine oil filtration
    • Medical Equipment Maintenance
      • CMM-0.6 X-ray Transformer Oil Purifier
      • AVSk-150 Hospital Wastewater Treatment Complex
    • Blending systems
      • USBL-1 Laboratory Blending System
      • USB-1 Fuel oil blending system
      • USB-5 high-speed mixing unit for production of sanitizers (0.15 – 0.3 m³/h)
      • USB-5 high-speed mixing unit for production of sanitizers (1.1 m3/cycle)
      • USB-6 Impeller Stirrer
      • Colloid Mill
      • Vortex Layer Devices
    • Colloid Mill
      • Colloid mills for food industry
        • CLM-100.3 Colloid mill
      • Colloid mills for bitumen emulsion production
        • CLM-0.25.1 Laboratory colloid mill
        • CLM-2/4 Colloid mill
        • CLM-16/25 Colloid mill
      • Colloid mills for bitumen modification
        • CLM-8/16 Colloid mill
        • CLM-10/20 Colloid mill
        • CLM-40.2 Colloid Mill
      • Colloid mills for different applications
        • CLM-100.2 Colloid Mill
        • CLM-200.2 Colloid Mill
    • Vortex Layer Devices
      • AVS-100 Mixing Machine. Vortex Layer Device
      • AVS-150 Chemical Mixing Machine
      • AVSp-100 Vortex Layer Device (Semi-Automated)
      • AVSp-150 vortex layer device (semi-automated)
      • AVSk-150 Wastewater Treatment Complex
    • Bitumen emulsion plant, Bitumen Emulsion Production
      • CLM-0.25.1 Laboratory colloid mill
      • USB-2 Bitumen emulsion unit 2 m3/hour production capacity
      • USB-2 Bitumen emulsion plant 8 m3/hour production capacity
      • FB Bitumen filter
      • USB-6 Impeller Stirrer
    • Bitumen Modification Plant. Modified Bitumen Production
      • USB-3 Bitumen modification laboratory system
      • USB-3 Continuous Bitumen Modification Unit (12 m3/hour)
      • USB-3 Bitumen modification unit 16 m3/hour production capacity
      • USB-4 Modified bitumen collection tank (USB-3)
      • USB-6 Impeller Stirrer
    • Laboratory system for Bitumen Emulsion Samples
      • CLM-0.25.1 Laboratory colloid mill
      • CLM-100.1 Bitumen Emulsion Laboratory System
      • USB-3 Bitumen modification laboratory system
    • Biodiesel Equipment
      • USB-1L Biodiesel laboratory equipment
      • USB-1 Biodiesel equipment
        • Filters
          • The filter GC Fine with a filtration factor β = 4000
        • Vacuum Pumps
          • GC Roots Vacuum Pumps
          • مضخات التفريغ GC Vane (مضخات دعم)
    • Custom Equipment
      • CMM-4R TRANSFORMER OIL REGENERATION MACHINE
      • CMM-1 MOBILE OIL PLANT
      • CMM-2.2 MOBILE OIL PLANT
      • CMM-4 MOBILE UNIT FOR POWERED TRANSFORMER OIL PROCESSING
      • CMM-12A DEGASSING UNIT
      • CMM-1CO CABLE OIL DEGASSING UNIT
      • CMM-5M INDUSTRIAL OIL PURIFICATION MACHINE
      • CMM-8RP Sorbent Reactivation Unit
      • BDK-3 CATALYTIC CONVERTER
      • CMM-600CF TRANSFORMER OIL FILTRATION AND REFILLING MACHINE
      • SN-1 PUMP ASSEMBLY
      • SBE-30 BITUMEN EMULSION COLLECTION TANK (UVB-1)
      • UVB-1 BITUMEN EMULSION UNIT 1 M3/HOUR PRODUCTION CAPACITY
      • UVB-1 EXTENSION 1 M3/HOUR PRODUCTION CAPACITY
      • INDUSTRIAL MIXER – COLLOID MILLS CLM-4 SMALL
      • BIG COLLOIDAL MILL CLM-18 GRINDING MACHINE
      • INDUSTRIAL MILL – GIANT COLLOIDAL MILL CLM-22
      • CMM-0.6 Clean Marine Oil Degassing Cart
      • Compressed Air Supply Unit UOV
    • Accessories & Components
  • Dealers
  • Tech School
    • Webinar Registration
  • News & Articles
  • History
  • Reviews
  • AskMe
  • Contacts
EN EN ▼
  • PT-PT PT-PT
  • FR FR
  • ES ES
  • DE DE
  • AR AR
  • PL PL
  • UA UA
  • ID ID
  • VN VN
  • IT IT
  • GE GE
  • UZ UZ
  • CN CN
  • KZ KZ
  • CZ CZ

Smart search

GlobeCore / Transformer Maintenance / How to Detect a Dangerous Increase in Hydrogen Concentration in a Transformer?

How to Detect a Dangerous Increase in Hydrogen Concentration in a Transformer?

How to Detect a Dangerous Increase in Hydrogen Concentration in a Transformer?

Hydrogen is one of the earliest indicators that something is wrong with a transformer’s insulation. It appears in the insulating oil before most other fault gases and often signals processes that can eventually lead to serious equipment failure. The challenge is that many utilities and industrial facilities only discover rising hydrogen levels after a dissolved gas analysis (DGA) report reveals critical values—typically from laboratory tests performed quarterly or even annually. By then, the defect may have progressed to a stage where repairs are far more expensive than preventive maintenance.

This article explains why hydrogen deserves special attention and outlines the most practical methods for monitoring it.

Why Hydrogen Matters More Than Other Gases

When insulating oil decomposes due to elevated temperatures or electrical discharges, hydrogen is typically the first gas to form—and often in the greatest quantity. It begins to evolve at temperatures of approximately 150°C (302°F) and can account for up to 59% of the total gas volume generated during oil decomposition.

Hydrogen is also produced during partial discharges, where ionization breaks the weakest hydrocarbon bonds in the insulating oil, leading to a gradual accumulation of hydrogen.

One of hydrogen’s greatest advantages as a diagnostic indicator is its physical behavior. Although it has relatively low solubility in insulating oil, it diffuses through the oil very quickly. As a result, even a small amount generated at a localized fault—for example, near a partial discharge—rapidly spreads throughout the oil, making it detectable long before the defect becomes critical.

Method 1: Periodic On-Site Express Testing

If continuous online monitoring is unnecessary or impractical, the minimum recommended approach is regular on-site measurement of hydrogen and moisture without sending oil samples to a laboratory.

This can be accomplished using a TOR-2 portable express tester, which measures hydrogen and moisture content (ppm) in transformer oil as well as other mineral and ester insulating fluids.

The primary advantage of this method is speed and repeatability. A measurement takes only a few minutes instead of several days or weeks required for laboratory analysis. This makes it practical to perform tests as frequently as needed—weekly, monthly, or during scheduled maintenance inspections.

More important than a single measurement is the trend. If hydrogen concentration consistently increases from one inspection to the next, further diagnostic investigation is recommended even if the absolute value has not yet reached a critical level.

Method 2: Continuous Online Monitoring

For particularly critical transformers-where a defect can develop within hours, where the equipment is located at a remote substation, or where partial discharge activity is already suspected-even weekly manual measurements leave significant periods without information.

In these situations, continuous monitoring with the TOR-5 system is a more appropriate solution. The hydrogen sensor is available as an optional addition to the system’s standard moisture monitoring configuration.

Compared with laboratory testing or periodic measurements using the TOR-2, continuous monitoring provides several practical advantages:

  • Measurements are recorded every minute, 24/7, rather than once a week or once a month. A rapid increase in hydrogen becomes visible the same day instead of weeks later.
  • Data is transmitted via a cellular connection directly to the cloud, eliminating the need to visit the site to check transformer condition. Hydrogen concentration trends are available remotely at any time.
  • The system calculates additional diagnostic parameters-including insulation condition and estimated oil breakdown voltage—based on sensor data, providing a more comprehensive assessment than hydrogen measurements alone.
  • If moisture exceeds preset limits, the connected oil drying and filtration unit can start automatically without operator intervention, regardless of the time of day or whether personnel are on site.

The key advantage over periodic measurements is not higher measurement accuracy, but faster detection of changing trends. Instead of discovering a developing problem days or weeks later, operators can identify abnormal behavior almost as soon as it begins.

Choosing the Right Approach

If a transformer is relatively new, operating under stable conditions, and there are no signs of active fault development, periodic testing with the TOR-2 during scheduled maintenance is generally sufficient. It is cost-effective, easy to implement, and still provides valuable trend information over time.

If the transformer is older, critical to production, located far from maintenance personnel, or there are already indications of partial discharges or overheating, continuous monitoring with the TOR-5 equipped with the optional hydrogen sensor is the better choice. It allows dangerous changes to be detected immediately rather than after the fact.

A dangerous increase in hydrogen concentration is rarely identified by looking at a single measurement. What truly matters is how rapidly hydrogen levels change over time.

The most important practical rule is simple: if hydrogen concentration rises significantly between successive measurements, immediate investigation is warranted-even if the measured value is still below traditional alarm thresholds.

The objective is not merely to measure hydrogen once, but to establish a monitoring strategy that makes it impossible to miss a developing trend—whether through regular testing with a portable analyzer or through continuous real-time online monitoring.