GlobeCore.com

  • Home
  • Products
    • Oil Regeneration
      • CMM-6RL Oil Regeneration Unit
      • CMM-10RL Transformer Oil Regeneration Plant
      • CMM-12R Oil Regeneration Systems
      • CMM-12R Oil Regeneration System (With Activated Bauxite)
      • CMM-8RSL/4000 Transformer Oil Regeneration Plant (With Fuller’s Earth)
      • USB-6 Oxidation Inhibitor injection unit
      • СММ-0,001U Laboratory Oil Filtration Unit
    • Oil Purification & Degassing Machines
      • CMM-0.6L Oil Degassing & Filtration Cart
      • СММur-1L mobile oil plant
      • CMM-1.0LT Transformer Oil Purification Unit
      • CMM-1H Oil Processing Unit
      • CMM-2.2LT Industrial Oil Purification Unit
      • CMM-4,0T Turbine oil filtration
      • CMM-4,0LT Transformer Oil Purification Unit
      • CMM-4/7 portable oil degassing unit
      • CMM-6LT Industrial Oil Purification Unit
      • CMM-6/7 Degassing Unit
      • CMM-8LT Oil Processing Unit
      • CMM-10 — Transformer Oil Purification Machine
      • CMM-15 Oil Degassing Plant
    • Oil Filtration Machines
      • CMM-1,0CF Unit for Removal of Water from Oil
      • CMM-2,0CF Unit for Removal of Water from Oil
      • CMM-1,2Fr Industrial oils filtration unit with self-cleaning filters
      • CMM-4,0F Oil filtration unit
    • Oil Drying Unit
      • ZP-130 Sorbent Cartridges
      • ZP-260 Sorbent Cartridges
    • Oil Heating
      • PPM Inline Oil Heater. Stream oil heating
    • Fuel Polishing
      • TOR-1 diesel fuel moisture content tester
      • CMM-6RL dark diesel fuel polishing machine
      • CMM-6RL dark heating fuel polishing machine
      • CMM-6RL low-viscosity marine fuel polishing machine
    • Online Transformer Dry-Out Systems
      • CMM-260C Online Transformer Dry-Out System
      • TOR-4 Online Transformer Dry-Out System
    • Online Transformer Monitoring Systems
      • TOR-5 Online Transformer Monitoring System
    • Transformer Maintenance
      • Mojave Heat (Sukhovey): Hot Air Dryer Unit
      • UVV Vacuum Cold Trap
      • US-6S Transformer Drying Oven
      • LFD Low Frequency Heating Device
      • BV-3000 Transformer Evacuation System
      • BV-5000 Transformer Evacuation System
      • UVD Vacuum Oil Filling Unit
      • UVD-1000 Oil Filling and Transportation System
      • TSS Transformer Safety System
      • CMM-6RL Oil Regeneration Unit
      • CMM-10RL Transformer Oil Regeneration Plant
      • CMM-12R Oil Regeneration Systems
    • Vacuum Transformer Drying Ovens
      • US-6S Transformer Drying Oven
    • Sorbent Processing
      • ZP-130 Sorbent Cartridges
      • ZP-260 Sorbent Cartridges
    • Instruments – Transformer Oil Testers
      • TOR-1 Oil Moisture Meter
      • TOR-2 Hydrogen and Moisture Analyzer for Transformer Oil Monitoring
      • TOR-3 (TOR-3 SL) Oil Tan Delta Tester
      • TOR-6 Transformer Oil Moisture and Particles Tester
      • TOR-7 Universal Transformer Oil Tester (moisture, gases, solid particles)
      • TOR-8 tester for residual gas content of insulating oil
      • TOR-60 (TOR-60 SL) Breakdown Voltage Tester
      • TOR-80 (TOR-80 LSL) Breakdown Voltage Tester
      • TOR-80A (TOR-80 ASL) Transformer Oils Breakdown Voltage Tester with Battery
      • TOR-100 (TOR-100 SL) Breakdown Voltage Tester
    • Wind Turbine Service
      • CMM-G wind turbine gearbox oil changer (with dimensions adapted to the customer’s trailer ones)
      • CMM-G Wind Turbine Gearbox Oil Changer
      • CMM-GL Wind Turbine Gearbox Oil Changer
      • CMM-0.6L Oil Degassing & Filtration Cart
      • CMM-4,0T Turbine oil filtration
    • Medical Equipment Maintenance
      • CMM-0.6 X-ray Transformer Oil Purifier
      • AVSk-150 Hospital Wastewater Treatment Complex
    • Blending systems
      • USBL-1 Laboratory Blending System
      • USB-1 Fuel oil blending system
      • USB-5 high-speed mixing unit for production of sanitizers (0.15 – 0.3 m³/h)
      • USB-5 high-speed mixing unit for production of sanitizers (1.1 m3/cycle)
      • USB-6 Impeller Stirrer
      • Colloid Mill
      • Vortex Layer Devices
    • Colloid Mill
      • Colloid mills for food industry
        • CLM-100.3 Colloid mill
      • Colloid mills for bitumen emulsion production
        • CLM-0.25.1 Laboratory colloid mill
        • CLM-2/4 Colloid mill
        • CLM-16/25 Colloid mill
      • Colloid mills for bitumen modification
        • CLM-8/16 Colloid mill
        • CLM-10/20 Colloid mill
        • CLM-40.2 Colloid Mill
      • Colloid mills for different applications
        • CLM-100.2 Colloid Mill
        • CLM-200.2 Colloid Mill
    • Vortex Layer Devices
      • AVS-100 Mixing Machine. Vortex Layer Device
      • AVS-150 Chemical Mixing Machine
      • AVSp-100 Vortex Layer Device (Semi-Automated)
      • AVSp-150 vortex layer device (semi-automated)
      • AVSk-150 Wastewater Treatment Complex
    • Bitumen emulsion plant, Bitumen Emulsion Production
      • CLM-0.25.1 Laboratory colloid mill
      • USB-2 Bitumen emulsion unit 2 m3/hour production capacity
      • USB-2 Bitumen emulsion plant 8 m3/hour production capacity
      • FB Bitumen filter
      • USB-6 Impeller Stirrer
    • Bitumen Modification Plant. Modified Bitumen Production
      • USB-3 Bitumen modification laboratory system
      • USB-3 Continuous Bitumen Modification Unit (12 m3/hour)
      • USB-3 Bitumen modification unit 16 m3/hour production capacity
      • USB-4 Modified bitumen collection tank (USB-3)
      • USB-6 Impeller Stirrer
    • Laboratory system for Bitumen Emulsion Samples
      • CLM-0.25.1 Laboratory colloid mill
      • CLM-100.1 Bitumen Emulsion Laboratory System
      • USB-3 Bitumen modification laboratory system
    • Biodiesel Equipment
      • USB-1L Biodiesel laboratory equipment
      • USB-1 Biodiesel equipment
        • Filters
          • The filter GC Fine with a filtration factor β = 4000
        • Vacuum Pumps
          • GC Roots Vacuum Pumps
          • مضخات التفريغ GC Vane (مضخات دعم)
    • Custom Equipment
      • CMM-4R TRANSFORMER OIL REGENERATION MACHINE
      • CMM-1 MOBILE OIL PLANT
      • CMM-2.2 MOBILE OIL PLANT
      • CMM-4 MOBILE UNIT FOR POWERED TRANSFORMER OIL PROCESSING
      • CMM-12A DEGASSING UNIT
      • CMM-1CO CABLE OIL DEGASSING UNIT
      • CMM-5M INDUSTRIAL OIL PURIFICATION MACHINE
      • CMM-8RP Sorbent Reactivation Unit
      • BDK-3 CATALYTIC CONVERTER
      • CMM-600CF TRANSFORMER OIL FILTRATION AND REFILLING MACHINE
      • SN-1 PUMP ASSEMBLY
      • SBE-30 BITUMEN EMULSION COLLECTION TANK (UVB-1)
      • UVB-1 BITUMEN EMULSION UNIT 1 M3/HOUR PRODUCTION CAPACITY
      • UVB-1 EXTENSION 1 M3/HOUR PRODUCTION CAPACITY
      • INDUSTRIAL MIXER – COLLOID MILLS CLM-4 SMALL
      • BIG COLLOIDAL MILL CLM-18 GRINDING MACHINE
      • INDUSTRIAL MILL – GIANT COLLOIDAL MILL CLM-22
      • CMM-0.6 Clean Marine Oil Degassing Cart
      • Compressed Air Supply Unit UOV
    • Accessories & Components
  • Dealers
  • Tech School
    • Webinar Registration
  • News & Articles
  • History
  • Reviews
  • AskMe
  • Contacts
EN ▼
  • PT-PT
  • FR
  • ES
  • DE
  • AR
  • PL
  • UA
  • ID
  • VN
  • IT
  • GE
  • UZ
  • CN
  • KZ
  • CZ
  • NL
    TR
    JP
    CZ
    DK
    FI
    GR
    IL
    IN
    HU
    KR
    NO
    RO
    SK
    SI
    SE
    TH
    BG
    HR
    EE
    LT
    LV
    MY
    IR
NL
TR
JP
CZ
DK
FI
GR
IL
IN
HU
KR
NO
RO
SK
SI
SE
TH
BG
HR
EE
LT
LV
MY
IR

Smart search

GlobeCore / Transformer Maintenance / How to Prevent Moisture Accumulation in Transformer Oil

How to Prevent Moisture Accumulation in Transformer Oil

How to Prevent Moisture Accumulation in Transformer Oil

Moisture is one of the greatest threats to a power transformer. It rarely manifests itself through a sudden failure or an immediate protection trip; instead, it accumulates gradually, year after year, until one day it reveals itself through reduced insulation dielectric strength, shortened service life, or, in the worst case, an internal short circuit.

Why Moisture in Transformer Insulation Is So Dangerous

Cellulose (paper/pressboard) insulation inside a transformer is arguably its most valuable component. Its condition largely determines how long the transformer can remain safely in service.

A key fact about insulation aging is that the aging rate of cellulose insulation depends heavily on temperature.

Temperature Insulation Aging Time
100 °C ≈ 20 years
110 °C ≈ 5 years

This is why, under normal operating conditions, replacing power transformers simply because they have reached their nominal 25-year service life is often not economically justified. In many cases, the equipment still retains a significant remaining service life.

The problem is that moisture does not wait for a convenient moment to accumulate. After 25-30 years of operation, the moisture content of the insulation may reach a level that significantly affects transformer reliability and remaining service life. The rate of moisture accumulation is directly related to the operating load the transformer has carried throughout its lifetime.

Why a Conventional Major Overhaul Is Not the Best Way to Combat Moisture

Restoring insulation moisture content to an acceptable level usually requires a major overhaul, and insulation drying is one of the most time-consuming stages of this process.

  • Insulation drying may account for 25-50% of the total overhaul duration.
  • The larger the transformer, the more difficult the process becomes due to the greater volume and mass of insulation.
  • Conventional drying methods (high temperature and vacuum) may themselves damage insulation that has already been weakened by aging.
  • A complete overhaul setup is required, and the work is often limited to seasons with above-freezing ambient temperatures.
  • Opening the transformer tank under field conditions introduces additional risks.

For both technical and economic reasons, it is far more practical to keep insulation moisture within safe limits continuously than to attempt to correct the problem during the limited window of a scheduled overhaul.

Where Moisture Actually Comes From

In a sealed transformer, there are essentially only two sources of moisture.

1. The Atmosphere

Imperfections in transformer design or maintenance (seals, breathers, gaskets) gradually allow external moisture to enter.

Typical accumulation rate: 0.03-0.05% per year

2. Aging as a By-Product

Oxidation and thermal aging of cellulose insulation and transformer oil are unavoidable throughout the transformer’s service life. Moisture is one of the natural by-products of these processes.

Typical accumulation rate: 0.04-0.05% per year

What This Looks Like in Numbers

Stage Moisture Content of Solid Insulation
After manufacturing 0.5-0.8%
Immediately after installation no more than ≈ 1%
After 25 years of operation (estimated) 2.7-3.0%
Generally accepted safe limit no more than ≈ 2%

A Common Misconception

The presence of transformer oil does not protect solid insulation from absorbing moisture – it merely slows the process down. Moisture continuously migrates between the oil and the paper.

The ability of transformer oil to retain water depends strongly on temperature, whereas the moisture saturation point of paper remains approximately 17%, regardless of temperature. In other words, the paper will continue absorbing moisture from the oil for a very long time before equilibrium is reached.

Why Elevated Insulation Moisture Is Dangerous

Excess moisture in solid insulation is not just another number in a test report. In practice, it:

  • increases the risk of internal short circuits;
  • makes future repairs more difficult and time-consuming, reducing the interval between overhauls;
  • directly reduces the transformer’s remaining useful service life;
  • lowers the maximum temperature the insulation can safely withstand, effectively reducing the transformer’s overload capability.

Why Moisture Is So Difficult to Measure Accurately

What Happens Why It Complicates Evaluation
Temperature decreases Moisture condenses into droplets on solid surfaces or forms conductive paths.
Temperature increases Moisture is released from wet insulation, while microcapillaries become filled with steam bubbles, increasing the risk of short circuits.
Temperature below 0 °C Water freezes into ice crystals, creating a risk of damage during energization.
Migration between layers Moisture migration rates from oil to paper and from paper to oil differ, making accurate assessment more difficult.

The situation is further complicated by the fact that up to 98% of all moisture inside a transformer is contained in the cellulose insulation, which is also the most difficult part to measure directly.

In practice, paper moisture is estimated indirectly from transformer oil moisture using equilibrium curves, whose accuracy improves as the sample temperature increases.

A Practical Solution: Continuous Gentle Drying Instead of Periodic Intervention

Since moisture accumulates continuously and most of it is concentrated in the transformer component that is the most difficult to dry – the cellulose insulation – the most effective long-term strategy is not a one-time drying campaign every few decades, but continuous filtration that keeps both the oil and the paper dry throughout the transformer’s service life.

This is precisely the gap filled by the CMM-260C continuous online oil drying unit.

How It Works

The unit is connected directly to the transformer.

Transformer oil is continuously circulated through adsorption columns.

As the oil passes through the columns, it releases moisture, which is retained by the sorbent.

Thanks to pore sizes specifically selected for water molecules, the sorbent does not absorb oxidation inhibitors, dissolved gases, or furan compounds. As a result, it does not affect the results of routine transformer diagnostics, including DGA, furan analysis, and other standard tests.

Why It Dries Not Only the Oil but Also the Solid Insulation

In a transformer operating under load, moisture is constantly migrating between the winding insulation and the transformer oil in an attempt to reach equilibrium.

By continuously maintaining the oil in a dry condition, the unit creates a stable concentration gradient that gradually draws moisture out of the cellulose through diffusion – without high temperatures, without vacuum, and without opening the transformer tank.

This is a much gentler process than conventional drying methods, which is especially important for insulation that has already aged and become mechanically weakened.

The unit provides a capacity of at least 30 L/h and can adsorb up to 9 liters of water during the service life of the sorbent.

Connection to the transformer takes less than one hour, and the unit is compatible with transformers of any manufacturer and any service age, whether newly installed or in operation for decades.

The process requires neither oil heating nor continuous operator supervision. The unit is available in two versions, with or without a protective enclosure.

Because it operates without heating and without continuous monitoring, the unit is also suitable for transformers installed in remote or hard-to-access locations.

 

    LEAVE YOUR REQUEST

    GlobeCore Related Products

    Remote transformer monitoring online

    TOR-4 Online Transformer Dry-Out System

    BV-5000 Transformer Evacuation Unit (Capacity 5000 m³/hour)

    TOR-5 Online Transformer Monitoring System

    БВ 2000

    BV-3000 Transformer Evacuation System

    UVV Vacuum Cold Trap

    Transformer Drying Unit

    CMM-260C Online Transformer Dry-Out System

    US-6S Transformer Drying Oven

    US-6S Transformer Drying Oven

    Air drying equipment

    Mojave Heat (Sukhovey): Hot Air Dryer Unit

    • Home
    • Products
    • Dealers
    • Tech School
    • Contacts

    ® Copyright by - 2026 © GlobeCore

    GlobeCore, Sadovskogo 14, Poltava, Ukraine, 36034

    This website uses cookies to improve your experience. By continuing to browse, you agree to our use of cookies. на We use cookies to improve your browsing experience. Read more in our Privacy Policy.