- Description
- Specification
- Advantages
- Configurator
- Webinars
- Payback period
- Video
- Gallery
- Publications
The unit is built as a self-contained unit with all components and operating assemblies protected by metal panels and easy opening gas-spring loaded doors on the sides and back of the unit. The “Containerized”unit is placed on a tandem axle trailer that is street legal and ready to be towed to any remote location.
The unit consists of a vacuum1Vacuum is space devoid of matter. An approximation to such vacuum is a region with a gaseous pressure much less than atmospheric pressure. chamber, input and output oil pumps, coarse and fine filters2Filter is a device which separates solids from fluids (liquids or gases) by adding a medium through which only the fluid can pass., oil trap, oil heater3Oil heating is used for treatment of oil in degassing, drying and regeneration machines to accelerate the process. Dehydration is based on the difference of water and oil boiling points. Since water boiling point is lower, heating can evaporate that water from the oil before the boiling point of oil is achieved., pipelines with valves, vacuum pump4A vacuum pump is a device that removes gas molecules from a sealed volume in order to leave behind a partial vacuum. section and a control cabinet.
| Parameter | Value |
| Capacity, m3/hour / gals. per hour: | |
|
10/2642 |
|
15/3970 |
| Processed oil parameters*: | |
|
0.1 |
|
10 ppm or 5 ppm or 5 ppm+ (optionally) |
|
1 |
| Oil output temperature in heating mode, ºС/ ºF | 90/194 |
| Outlet pressure, MPa | 0.4 |
| Max power consumption, kW | 200 |
| Residual pressure in vacuum chamber during degassing, Pa, max | 267 |
| Residual pressure in vacuum chamber during air tightness test, Pa, max | 26.7 |
| Air leak into the chamber in 1 hour, Pa max: | 267 |
| Electric power parameters | |
|
415 |
|
50/60 |
| Dimensions, mm, max (w/o trailer / with trailer) | |
|
2240/4365 |
|
1600/2270 |
|
1750/2300 |
| Weight, kg, max | 2350/3100 |
Note: * initial oil parameters:
- volumetric gas content – below 5%;
- mass moisture content – below 01% (100 g/ton);
- temperature – above 0 ºС/ 32 ºF.
**All equipment sold in the USA is designed to operate on 60 Hz AC Power
- transformer oil dielectric strength increase to at least 70 kV;
- transformer drying with simultaneous oil processing;
- initial filling of electrical equipment with insulation oil;
- evacuation of transformers and other electrical equipment;
- simple operation and servicing.
Components type is basic
Components type is premium
Manual performance adjustment by valves (or smooth performance adjustment, see option). Functioning in semi-automatic modes. Stepped or smooth (see option) oil heating. PLC control
Automatic performance adjustment. Functioning in automatic modes. Smooth oil heating. Control from PLC + HMI
Performance adjustment with manual valves
Performance adjustment of the oil pump is executed with a regulator on the control panel by means of a valve with an electric drive. Visual monitoring of the flow rate is by the flow meter indicator
Performance adjustment of the oil pump is executed by setpoint selecting at the control panel screen for maintaining the level in the vacuum column. Pump operation is smooth throughout the entire control range. There is a digital meter to control oil flow
The controller program switches the heater stages by contactors according to the algorithm. Operator sets the temperature and it is kept constant automatically
Solid state relay (SSR) adjusts the heater stages’ current smoothly and non-contactly. The P-Int-Derivative Controller
The language of text at the controller screen, devices, controls and the language of the technical documentation is English
The language of text at the controller screen, devices, controls and the language of the technical documentation is Spanish
The 10 ppm mode is the standard operating mode of the equipment, which involves drying oil using thermal vacuum technology.
The 5 ppm mode ensures a very low level of residual moisture in the oil by reducing machine productivity. This means that the equipment effectively removes even the smallest traces of water, which significantly extends the service life of the equipment.
The 5 ppm+ mode is an improved version that ensures even lower residual oil moisture levels by using sorbent cartridges and reducing machine productivity. This is ideal for critical applications especially for heavily loaded transformers with high demands.
Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit
Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which was processed by the unit
Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit and which was processed by the unit
Mechanical flow meter with total flow display
Digital flow meter with current and total flow display
The cable is fitted with an industrial sealed connector, consisting of an internal plug and a cable socket
The cable wires’ ends are fitted with a crimp terminals
The cable is fitted with an industrial sealed connector, consisting of an internal socket and a cable plug
No publications found.