GlobeCore / Application / Silicone transformer oil universal tester TOR-7

Silicone transformer oil universal tester TOR-7

Silicone transformer oil universal tester TOR-7

The TOR-7 silicone transformer oil universal tester made by GlobeCore is designed to test the main characteristics of dielectric liquids, including silicone oils used in transformers, circuit breakers and other electrical equipment. Silicone oils are pretty heat-stable and good at insulating, but their quality can change over time depending on the temperature, moisture, and other things outside. The TOR-7 lets you quickly and accurately measure electrical strength, moisture content, dielectric loss tangent and other important indicators. This data lets you check the oil’s condition regularly, spot early signs of ageing or contamination, and decide whether to keep going or replace the fluid. The device has electronic control, a touch panel and a screen for displaying results. All measurements are taken automatically, so there’s less room for human error and more accuracy. You can save or export the data for further analysis. TOR-7 is great for use in labs and on site in businesses. This device helps to keep equipment running smoothly and makes sure silicone oil in high voltage systems lasts longer.

Silicone transformer oil universal tester TOR-7 Specifications

Item Value
1 Measuring cell volume, l 1,2
2 Oil sample volume, l 0,5 – 0,7
3 Maximum pressure in the device, Pa 0,3
4 Maximum leakage in the device, Pa 26
5 Inlet oil pressure, bar 0,3 – 3
6 Temperature of measured oil, ºС 20 – 90
7 Maximum power consumption, kW, no more 1
8 Electrical current parameters: – voltage, V – variable with frequency, Hz    

Customer request

9 Overall dimensions, mm, not more than – length – height – width  

465

530

375

10 Weight, kg, not more than 40

Oil measurement characteristics

Item Value
Moisture measurement characteristics
1 Operating range, aw (water activity (aw)) 0…1
2 Accuracy at 20 °C ±0.02 aw (0…0.9 aw) ±0.03 aw (0.9…1 aw)
3 Temperature measurement yes
4 Working environment temperature, °C 0…55
Hydrogen measurement characteristics
6 Measuring range, ppm 25-5000
7 Accuracy 20% of measurement or 25 ppm
8 Repeatability 10% of measurement or 15 ppm
9 Response time <60 min (90% step change)
10 Cross Sensitivity Less than 2% cross-sensitivity to other gases (CO, CO2, Hydrocarbons)
11 Working environment temperature, °C 0…55
Contamination Measurement Characteristics
6 Measuring range, ppm 25-5000
7 Accuracy 20% of measurement or 25 ppm
8 Repeatability 10% of measurement or 15 ppm
9 Response time <60 min (90% step change)
10 Cross Sensitivity: Less than 2% cross-sensitivity to other gases (CO, CO2, Hydrocarbons)
11 Working environment temperature, °C 0…55
Characteristics of degree of purity or level of contamination
12 Acceptable viscosity range 1 to 1000 mm²/s
13 Measured variables ISO 99 (ISO 4406:1999)

SAE (SAE AS 4059) or

ISO 87 (ISO4406:1987)

NAS (NAS 1638)

14 Measurement range Measurement from ISO class 9/8/7 (MIN) to ISO class 25/24/23 (MAX)

Calibrated to ISO range from 11/13/10 to 23/21/18

15 Accuracy +/- ½ ISO class in calibrated range
16 Working environment temperature, °C 0 … +85

    Leave Your Request