Manual performance adjustment by valves (or smooth performance adjustment, see option). Functioning in semi-automatic modes. Stepped or smooth (see option) oil heating. PLC control

Automatic performance adjustment. Functioning in automatic modes. Smooth oil heating. Control from PLC + HMI

Frame open design

Shell is available

Performance adjustment with manual valves

Performance adjustment of the vacuum pump is executed with a regulator on the control panel by means of a valve with an electric drive. Visual monitoring of the flow rate is by the flow meter indicator

Performance adjustment of the vacuum pump is executed by setpoint selecting at the control panel screen for maintaining the level in the vacuum column. Setpoint is kept constant by means of a valve with an electric drive. Pump operation is smooth throughout the entire control range. There is a digital meter to control oil flow

The controller program switches the heater stages by contactors according to the algorithm. Operator sets the temperature and it is kept constant automatically

Solid state relay (SSR) adjusts the heater stages' current smoothly and non-contactly. The P-Int-Derivative Controller

Online monitoring the transformer tank oil level. Automatic shutdown of the procesing unit and automatic block of the oil hoses in case of an accident. Automatic performance adjustment option. Automatic smooth direct heating option

The language of text at the controller screen, devices, controls and the language of the technical documentation is English

The language of text at the controller screen, devices, controls and the language of the technical documentation is upon customer's request

Option to select the fine filter contaminant capacity

Option to select the fine filter contaminant capacity

Option to select the fine filter filtration degree

Option to select the fine filter filtration degree

Mechanical flow meter with total flow display

Digital flow meter with current and total flow display

Power supply analyzer displays the current, voltage, frequency by phases and other parameters

Industrial warmer with forced heat exchange to avoid condensation in the control cabinet

Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit

Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which was processed by the unit

Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit and which was processed by the unit

Sealing material: valve, rings, pump, gaskets

Sealing material: valve, rings, pump, gaskets

Four-wire flexible copper cable for external power supply

The cable is fitted with an industrial sealed connector, consisting of an internal plug and a cable socket

The cable wires' ends are fitted with a crimp terminals

The cable is fitted with an industrial sealed connector, consisting of an internal socket and a cable plug.