GlobeCore’s US-6S banks transformers vacuum drying oven is a piece of specialised equipment that is used to dry transformers properly before they are used. This unit is especially useful in important facilities like banks, where it’s crucial to have a steady supply of electricity. Transformers can get wet when they are being used or stored. This can reduce how well they can protect things from electricity and can even cause problems that could lead to an accident. The US-6S dries out the transformer by using low temperatures and a deep vacuum, which removes moisture from the inside of the transformer without damaging the insulation. The unit has a vacuum chamber, heating system, and precise temperature and pressure control. All the settings are controlled automatically, which makes sure the process is stable and safe. The US-6S from GlobeCore is a reliable solution for service companies and energy departments of banks. It helps to extend the service life of transformers and ensure their trouble-free operation in the most demanding conditions.
Banks transformers vacuum drying oven US-6S Specifications
No. | Parameter | Value |
Drying chamber | ||
1 | Internal dimensions, mm, max | |
– depth | 2,000 | |
– width | 1,300 | |
– height | 1,600 | |
Heating section | ||
2 | Heater power, kW | 45 |
3 | Temperature adjustment range, °С | 20…120 |
4 | Quantity of thermal electric heaters, pcs | 15 |
Vacuum section | ||
5 | Capacity, m3/h | 1,000 |
6 | Total power level of engines, kW | 11 |
7 | Achieved vacuum level, mbar | 1 |
Circulation system | ||
8 | Capacity, m3/h | 2,000 |
9 | Fan power, kW | 2.2 |
Exhaust system | ||
10 | Capacity, m3/h | 2,000 |
11 | Fan power, kW | 1.1 |
Condensation system | ||
12 | Chiller power, kW | 3.0 |
13 | Cooling performance of chiller, kcal/h | 6,000 |
14 | Condensation area, m2 | 7.5 |
15 | Heat exchanger (condenser) type | shell-and-tube |
Pneumatic system | ||
16 | Compressor power, kW | 1.1 |
17 | Pressure, bar | 9 |