GlobeCore / Products / Oil Regeneration / CMM-12R Oil Regeneration Systems

CMM-12R Oil Regeneration Systems

GlobeCore / Products / Oil Regeneration / CMM-12R Oil Regeneration Systems
The GlobeCore regeneration1Oil regeneration – is extraction of contaminants from oil in order to restore its original properties to be used equally...
    Advantages

    GlobeCore manufactures oil regeneration systems for both transformer manufacturers and for transformer service providers.

    GlobeCore units are loaded with a sorbent that captures all oil decomposition products.

    GlobeCore regeneration systems can use the same sorbent for up to 3 years before the first replacement.  No more need for consumables and costly labor related to replacement of exhausted sorbent on the job site.

    Regeneration systems can be combined with degassing units or can be purchased as stand-alone systems.

    GlobeCore regeneration systems can be used in combination with your existing degassing or drying unit.

    Each GlobeCore unit can be customized and includes a number of options:

    • An extra vacuum pump assembly for transformer vacuuming
    • Mounted on a trailer or a semi-trailer
    • Inlet and/or outlet moisture meters for the oil stream
    • Remote control and process monitoring via smartphone or PC
    • Climate Controlled Operator work room.

The GlobeCore regeneration1Oil regeneration – is extraction of contaminants from oil in order to restore its original properties to be used equally with fresh oils. process restores used oils to new like condition.  This process makes it possible to fill transformers2The term “transformer oil filling” has two meanings. The first is the process that compensates for the loss of oil in the course of transformer operation. The second is filling a transformer with oil before commissioning or after an overhaul. with oil that would previously have required disposal.  The oil in the transformer3A transformer is a static electrical device that transfers electrical energy between two or more circuits. can be used without replacement for the entire service life of the transformer.

The GlobeCore CMM-R systems are designed to extend transformer service life by restoring the dielectric strength4The term dielectric strength has the following meanings: 1) Of a pure insulating material, the maximum electric field that the material can withstand under ideal conditions without breaking down (i.e. without failure of its insulating properties). 2) For a specific configuration of dielectric material and electrodes, the minimum applied electric field (i.e. the applied voltage divided by electrode separation distance) that results in breakdown. This is the concept of breakdown voltage. and chemical composition of dielectric insulating oil5Insulating oil is an oil that is stable at high temperatures and has excellent electrical insulating properties..

In the process of oil regeneration, oil degradation products and acidic compounds are removed, the oil becomes clear, oxidation resistance is improved, while gas solubility is reduced.

Parameter

Value

1 Nominal capacity, l/h (gpm)

1000-2000 (4.4-8.8)

2 Oil losses during operation, %

2-25

3 Maximum allowed oil temperature, оС (оF)

90 (194)

4 Outlet pressure, bar (psi)

2,5 (36.25)

5 Maximum power consumption, kW

55

6 Rated vacuum suction speed, l/h (gpm)

280 000 (1232.8)

7 Fuller’s Earth mass, kg (lbs)

1600 (3527.4)

8 Electrical power parameters
Voltage, V

Customizable

Frequency, Hz
9 Coarse filtration fineness (mesh filter), µm

100

10 Pre-filtration fineness, µm

25

11 Fine filtration fineness, µm

5

12 Dimensions, mm (in)
Length

5500(217)

Width

2320 (91)

Height

2450 (96)

13 Weight, kg (lbs)

6000 (13227)

Regeneration of the oil in a transformer restores used oil to new like condition:

Parameter Before processing After processing
Moisture content by weight,g/t (ppm) as per IEC 733; ASTM D-1533 43 5
ISO 4406 industrial purity class -/18/16 -/14/12
Volumetric gas content % I.A.W.IEC 60599; ASTM D-3612 0.1
Acid number, mg KOH/g I.A.W IEC 296; ASTM D-664 0.2 0.01
Corrosive sulfur  I.A.W.*IEC 5662; ASTM D-1275 present absent
Dielectric strength, kV I.A.W. IEC 156; ASTM D-18116 30 70
Interfacial tension, N/m, at 25ºС  I.A.W.  IEC 6295; ASTM D-664 45
Dissipation factor at 90ºС  I.A.W.IEC 247; ASTM D-924 0.095 0.001
Oxidation stability I.A.W. IEC 74; 164 hours restored

(*I.A.W. In Accordance With)

Equipment configurations that are not included in this configurator can be implemented via a separate request to [email protected].

Aplication :

GlobeCore manufactures oil regeneration systems for both transformer manufacturers and for transformer service providers.

GlobeCore units are loaded with a sorbent that captures all oil decomposition products.

GlobeCore regeneration systems can use the same sorbent for up to 3 years before the first replacement.  No more need for consumables and costly labor related to replacement of exhausted sorbent on the job site.

Regeneration systems can be combined with degassing units or can be purchased as stand-alone systems.

GlobeCore regeneration systems can be used in combination with your existing degassing or drying unit.

Each GlobeCore unit can be customized and includes a number of options:

  • An extra vacuum pump assembly for transformer vacuuming
  • Mounted on a trailer or a semi-trailer
  • Inlet and/or outlet moisture meters for the oil stream
  • Remote control and process monitoring via smartphone or PC
  • Climate Controlled Operator work room.
Equipment configurations that are not included in this configurator can be implemented via a separate request to [email protected].

Aplication :

GlobeCore’s CMM-R units can be used for:

Equipment configurations that are not included in this configurator can be implemented via a separate request to [email protected].

Aplication :

Loading...

N/A - Basic components type

N/A
Available

N/A - Basic components type

N/A
Available

This unit adds DBPC (BHT) inhibitor into oil

Basic components type

All tanks and pipes are made of stainless steel

Frame open design

The unit is mounted in a metal container with removable metal hatches

The unit is mounted in a metal container with removable metal hatches. The walls and roof are thermally insulated

The unit is equipped with a heat-insulated operator's workplace with air conditioning (area about 7 m2)

Our TSS and options

The language of text at the controller screen, devices, controls and the language of the technical documentation is English

The language of text at the controller screen, devices, controls and the language of the technical documentation is upon customer's request

Mechanical flow meter with total flow display

Digital flow meter with current and total flow display

Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit

Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit and which was processed by the unit

Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit and which was processed by the unit

The cable is fitted with an industrial sealed connector, consisting of an internal plug and a cable socket

The cable wires' ends are fitted with a crimp terminals

The cable is fitted with an industrial sealed connector, consisting of an internal socket and a cable plug



Equipment configurations that are not included in this configurator can be implemented via a separate request to [email protected].

Aplication :

Equipment configurations that are not included in this configurator can be implemented via a separate request to [email protected].

Aplication :

Loading...
CMM-6RL
CMM-10RL
CMM-6R
CMM-12R


Equipment configurations that are not included in this configurator can be implemented via a separate request to [email protected].

Aplication :