November 5, 2025 at 11:14 pm by 山田 英樹
GlobeCore provides combined filtration and vacuuming units for transformer servicing. Systems include oil heating, degassing, and vacuum evacuation features. We will prepare a budgetary offer based on required flow rate and operation conditions.
-
June 30, 2026 at 6:56 am by Craig Price
In transformer service operations, mobile oil treatment systems are often preferred when flexibility and on-site deployment are required, especially in cases where transformers cannot be easily disconnected or transported.
These units typically combine several processing stages, including filtration, heating, and vacuum degassing, allowing simultaneous removal of moisture, gases, and mechanical impurities to restore oil dielectric properties.
The image below demonstrates a portable oil degassing and vacuum treatment unit designed for field operation, where compact skid-mounted design ensures mobility and efficient use during transformer maintenance activities. -
June 30, 2026 at 6:59 am by Matthew Johnson
The pictured skid-mounted unit is exactly the type of portable oil degassing and vacuum treatment equipment used for on-site transformer servicing: compact enough for field deployment, it combines oil heating, mechanical filtration and vacuum degassing to remove moisture, dissolved gases and particulate contamination and restore dielectric strength. Models in this class are designed for single-pass dehydration/degassing without adsorbents, operate quietly, and are optimized for transformer maintenance where the asset cannot be moved, including work on OLTCs and HV switchgear.
When selecting a unit, match the required throughput and filtration rating to the transformer size and oil condition, and consider options such as additional vacuum pump capacity for direct transformer evacuation, inline moisture meters for process control, trailer mounting or climate-controlled operator enclosures, and remote monitoring for site convenience. Pre‑heating the oil to lower viscosity and doing oil sampling before and after treatment will ensure you reach target moisture and dielectric levels; if you want, provide the transformer oil volume, initial water content and preferred processing rate and I can prepare a budgetary configuration and quote.