GlobeCore / Products / Oil Regeneration / CMM-12R Oil Regeneration Systems

CMM-12R Oil Regeneration Systems

GlobeCore / Products / Oil Regeneration / CMM-12R Oil Regeneration Systems
GlobeCore’s oil regeneration process restores used oils to a condition close to new oil. This process makes it possible to...
    Advantages

    **GlobeCore** manufactures oil regeneration systems for both transformer manufacturers and transformer service providers.

    **GlobeCore** units are loaded with a sorbent that captures all oil decomposition products.

    **GlobeCore** regeneration systems can use the same sorbent for up to 3 years before the first replacement. No more need for consumables and costly labor related to the replacement of exhausted sorbent at the job site.

    Regeneration systems can be combined with degassing units or purchased as stand-alone systems.

    **GlobeCore** regeneration systems can be used in combination with your existing degassing or drying unit.

    Each **GlobeCore** unit can be customized and includes a number of options:

    • Extra vacuum pump assembly for transformer vacuuming;
    • Mounted on a trailer or semi-trailer;
    • Moisture meters at the inlet and/or outlet of the oil stream;
    • Remote control and process monitoring via smartphone or PC;
    • Climate-controlled operator workroom.

GlobeCore’s oil regeneration process restores used oils to a condition close to new oil. This process makes it possible to fill transformers with oil that would otherwise have been disposed of. The oil can be used in the transformer without replacement throughout its entire service life.

GlobeCore’s CMM-R systems are designed to extend the transformer’s lifespan by restoring the dielectric strength and chemical composition of dielectric insulating oil.

In the oil regeneration process, oil degradation products and acidic compounds are removed, the oil becomes clear, oxidation resistance improves, while its gas solubility is reduced.

 

No.

Parameter

Value

1 Nominal capacity, l/h (gpm)

1000-2000 (4.4-8.8)

2 Oil losses during operation, %

2-25

3 Maximum allowed oil temperature, °C (°F)

90 (194)

4 Outlet pressure, bar (psi)

2.5 (36.25)

5 Maximum power consumption, kW

55

6 Rated vacuum suction speed, l/h (gpm)

280,000 (1232.8)

7 Fuller’s Earth mass, kg (lbs)

1600 (3527.4)

8 Electrical power parameters
Voltage, V

Customizable

Frequency, Hz
9 Coarse filtration fineness (mesh filter), µm

100

10 Pre-filtration fineness, µm

25

11 Fine filtration fineness, µm

5

12 Dimensions, mm (in)
Length

5500 (217)

Width

2320 (91)

Height

2450 (96)

13 Weight, kg (lbs)

6000 (13227)

Regeneration of the oil in a transformer restores used oil to new like condition:

Parameter Before processing After processing
Moisture content by weight, g/t (ppm) as per IEC 733; ASTM D-1533 43 5
ISO 4406 industrial purity class -/18/16 -/14/12
Volumetric gas content % I.A.W. IEC 60599; ASTM D-3612 0.1
Acid number, mg KOH/g I.A.W IEC 296; ASTM D-664 0.2 0.01
Corrosive sulfur I.A.W.* IEC 5662; ASTM D-1275 present absent
Dielectric strength, kV I.A.W. IEC 156; ASTM D-18116 30 70
Interfacial tension, N/m, at 25ºC I.A.W. IEC 6295; ASTM D-664 45
Dissipation factor at 90ºC I.A.W. IEC 247; ASTM D-924 0.095 0.001
Oxidation stability I.A.W. IEC 74; 164 hours restored

(*I.A.W. In Accordance With)

Aplication :

**GlobeCore** manufactures oil regeneration systems for both transformer manufacturers and transformer service providers.

**GlobeCore** units are loaded with a sorbent that captures all oil decomposition products.

**GlobeCore** regeneration systems can use the same sorbent for up to 3 years before the first replacement. No more need for consumables and costly labor related to the replacement of exhausted sorbent at the job site.

Regeneration systems can be combined with degassing units or purchased as stand-alone systems.

**GlobeCore** regeneration systems can be used in combination with your existing degassing or drying unit.

Each **GlobeCore** unit can be customized and includes a number of options:

  • Extra vacuum pump assembly for transformer vacuuming;
  • Mounted on a trailer or semi-trailer;
  • Moisture meters at the inlet and/or outlet of the oil stream;
  • Remote control and process monitoring via smartphone or PC;
  • Climate-controlled operator workroom.

Aplication :

**GlobeCore**’s CMM-R units can be used for:

  • Transformer oil regeneration;
  • Electric train traction transformer oil regeneration;
  • Turbine oil regeneration;
  • Hydraulic oil regeneration;
  • Gear oil regeneration;
  • Industrial oil regeneration;
  • Silicone oil regeneration;
  • Oil bleaching;
  • Regeneration of dielectric fluid Midel 7131;
  • Regeneration of FR3 dielectric fluids;
  • Gas condensate polishing;
  • Marine fuel polishing;
  • Diesel fuel polishing;
  • Fuel oil polishing;
  • Boat fuel polishing.

Aplication :

Loading...

N/A - Basic components type

N/A
Available

N/A - Basic components type

N/A
Available

This unit adds DBPC (BHT) inhibitor into oil

Basic components type

All tanks and pipes are made of stainless steel

Frame open design

The unit is mounted in a metal container with removable metal hatches

The unit is mounted in a metal container with removable metal hatches. The walls and roof are thermally insulated

The unit is equipped with a heat-insulated operator's workplace with air conditioning (area about 7 m2)

Our TSS and options

The language of text at the controller screen, devices, controls and the language of the technical documentation is English

The language of text at the controller screen, devices, controls and the language of the technical documentation is upon customer's request

Mechanical flow meter with total flow display

Digital flow meter with current and total flow display

Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit

Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit and which was processed by the unit

Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit and which was processed by the unit

The cable is fitted with an industrial sealed connector, consisting of an internal plug and a cable socket

The cable wires' ends are fitted with a crimp terminals

The cable is fitted with an industrial sealed connector, consisting of an internal socket and a cable plug



Aplication :

Aplication :

Loading...
CMM-6RL
CMM-10RL
CMM-6R
CMM-12R


Aplication :